Read the docs
TI-2023-18802 Aliases CVE-2023-37144GHSA-wcfv-v4fh-j2vc

Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via…

Priority HIGH 82CWE-77Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-77.

Summary

Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.

Why it matters now

Exploitation Proof of concept CISA SSVC · not in CISA KEV
EPSS 0.02446 84th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Poc
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:tendacn:ac10_firmware:15.03.06.26:*:*:*:*:*:*:*15.03.06.26VulnerableTendacn
cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*not specified by NVDRunning onTenda
  • cpe:2.3:o:tendacn:ac10_firmware:15.03.06.26:*:*:*:*:*:*:* Versions 15.03.06.26 Vulnerable ·Tendacn
  • cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Tenda

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-37144
  2. 2026-10-03 Alias added: GHSA-wcfv-v4fh-j2vc

References

  • TI-2021-15902 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the urls… CVSS 3.1CRITICAL 9.8
  • TI-2018-11700 An issue was discovered on Tenda AC9 V15.03.05.19(6318)_CN and AC10 V15.03.06.23_CN… CVSS 3.0HIGH 8.8
  • TI-2018-11699 An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10… CVSS 3.0HIGH 7.5
  • TI-2022-09646 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow in the setSmartPowerManagement function. CVSS 3.1HIGH 7.5
  • TI-2021-16308 Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list… CVSS 3.1HIGH 7.5
  • TI-2018-10393 Tenda AC7 through V15.03.06.44_CN, AC9 through V15.03.05.19(6318)_CN, and AC10 through… CVSS 3.0HIGH 7.5

Sources