TI-2019-04854 Aliases CVE-2019-6821GHSA-pr9h-xjrf-gjcr

CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the…

Priority LOW 33CWE-330Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
Low · Low · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

CWE-330: Use of Insufficiently Random Values vulnerability, which could cause the hijacking of the TCP connection when using Ethernet communication in Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum.

Why it matters now

EPSS 0.0193 80th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon QuantumModicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum—No fix listedCNA
  • Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum Vendor— Affected Modicon Controllers, Modicon M580 firmware versions prior to V2.30, and all firmware versions of Modicon M340, Modicon Premium, Modicon Quantum Fixed in — No fix listed CNA

CPE configurations NVD · 8

CPEVersionsRoleVendor
cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*before 2.30VulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:*all versionsVulnerableSchneider Electric
cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*not specified by NVDRunning onSchneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:* Versions before 2.30 Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric
  • cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:* Versions all versions Vulnerable ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-6821
  2. 2026-10-03 Alias added: GHSA-pr9h-xjrf-gjcr

References

  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
  • TI-2018-05680 Authentication bypass by spoofing in Modicon M580 Modicon M340 Modicon Quantum Modicon… CVSS 3.1CRITICAL 9.8
  • TI-2018-05684 Exposure of resource to wrong sphere in Modicon M580 Modicon M340 Modicon Quantum Modicon… CVSS 3.1CRITICAL 9.8
  • TI-2019-04884 Information disclosure in Modicon M580, Modicon M340, Modicon Premium , Modicon Quantum CVSS 3.1HIGH 7.5
  • TI-2019-04843 Missing authentication in Modicon M580 Modicon M340 Modicon Quantum Modicon Premium CVSS 3.1CRITICAL 9.8
See all 38 →