TI-2019-13264 Aliases CVE-2019-18247GHSA-gr3p-h56x-rc2c

Improper input validation in Relion 650 and 670 Series

Priority LOW 36CWE-20Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

An attacker may use a specially crafted message to force Relion 650 series (versions 1.3.0.5 and prior) or Relion 670 series (versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior) to reboot, which could cause a denial of service.

Why it matters now

EPSS 0.01551 75th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
—Relion 650 and 670 SeriesRelion 650 series versions 1.3.0.5 and prior, Relion 670 series versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior—No fix listedCNA
  • Relion 650 and 670 Series Vendor— Affected Relion 650 series versions 1.3.0.5 and prior, Relion 670 series versions 1.2.3.18, 2.0.0.11, 2.1.0.1 and prior Fixed in — No fix listed CNA

CPE configurations NVD · 5

CPEVersionsRoleVendor
cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:*up to 1.3.0.5VulnerableHitachi Energy
cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*not specified by NVDRunning onHitachi Energy
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*up to 1.2.3.18VulnerableHitachi Energy
cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*not specified by NVDRunning onHitachi Energy
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*2.0.0 – 2.0.0.11; 2.1.0 – 2.1.0.1VulnerableHitachi Energy
  • cpe:2.3:o:hitachienergy:relion_650_firmware:*:*:*:*:*:*:*:* Versions up to 1.3.0.5 Vulnerable ·Hitachi Energy
  • cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:* Versions up to 1.2.3.18 Vulnerable ·Hitachi Energy
  • cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:* Versions 2.0.0 – 2.0.0.11; 2.1.0 – 2.1.0.1 Vulnerable ·Hitachi Energy

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2019-18247
  2. 2026-10-03 Alias added: GHSA-gr3p-h56x-rc2c

References

  • TI-2022-03099 IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products CVSS 3.1HIGH 7.5
  • TI-2021-14266 Insufficient Security Control Vulnerability CVSS 3.1HIGH 8.1
  • TI-2021-08743 Specially Crafted IEC 61850 Protocol Sequence Vulnerability CVSS 3.1HIGH 7.5
  • TI-2021-14265 Insufficient Security Control Vulnerability CVSS 3.1HIGH 7.2
  • TI-2023-04170 A vulnerability exists in the input validation of the GOOSE messages where out of range… CVSS 3.1HIGH 7.5
  • TI-2022-03542 Improper signature verification in Hitachi Energy Relion 670/650/SAM600-IO Series CVSS 3.1MEDIUM 4.5

Sources