TI-2021-14266 Aliases CVE-2021-35535GHSA-v26g-w7c2-rjj3

Insufficient Security Control Vulnerability

Priority LOW 36CWE-1188Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
High
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA.

Summary

Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network port and to cause a reboot sequences of the device may exploit the vulnerability, where there is a tiny time gap during the booting process where an older version of VxWorks is loaded prior to application firmware booting, could exploit the vulnerability in the older version of VxWorks and cause a denial-of-service on the product. This issue affects: Hitachi Energy Relion 670 Series 2.2.2 all revisions; 2.2.3 versions prior to 2.2.3.3. Hitachi Energy Relion 670/650 Series 2.2.0 all revisions; 2.2.4 all revisions. Hitachi Energy Relion 670/650/SAM600-IO 2.2.1 all revisions.

Why it matters now

EPSS 0.00667 52nd percentileScored 2026-11-07
Fix Fixed Relion 670 Series (Hitachi Energy): 2.2.3.3

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Hitachi EnergyRelion 670 Series2.2.2 all revisions; 2.2.3 to before 2.2.3.32.2.3.3Patch availableCNA
Hitachi EnergyRelion 670/650 Series2.2.0 all revisions; 2.2.4 all revisions—No fix listedCNA
Hitachi EnergyRelion 670/650/SAM600-IO2.2.1 all revisions—No fix listedCNA
  • Relion 670 Series VendorHitachi Energy Affected 2.2.2 all revisions; 2.2.3 to before 2.2.3.3 Fixed in 2.2.3.3 Patch available CNA
  • Relion 670/650 Series VendorHitachi Energy Affected 2.2.0 all revisions; 2.2.4 all revisions Fixed in — No fix listed CNA
  • Relion 670/650/SAM600-IO VendorHitachi Energy Affected 2.2.1 all revisions Fixed in — No fix listed CNA

CPE configurations NVD · 12

CPEVersionsRoleVendor
cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:*2.2.3 – 2.2.3.3VulnerableHitachi Energy
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.0:*:*:*:*:*:*:*2.2.0VulnerableHitachi Energy
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.1:*:*:*:*:*:*:*2.2.1VulnerableHitachi Energy
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.2:*:*:*:*:*:*:*2.2.2VulnerableHitachi Energy
cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.4:*:*:*:*:*:*:*2.2.4VulnerableHitachi Energy
cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:*not specified by NVDRunning onHitachi Energy
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.0:*:*:*:*:*:*:*2.2.0VulnerableHitachi Energy
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:*2.2.1VulnerableHitachi Energy
cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.4:*:*:*:*:*:*:*2.2.4VulnerableHitachi Energy
cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:*not specified by NVDRunning onHitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:*:*:*:*:*:*:*:* Versions 2.2.3 – 2.2.3.3 Vulnerable ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.0:*:*:*:*:*:*:* Versions 2.2.0 Vulnerable ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.1:*:*:*:*:*:*:* Versions 2.2.1 Vulnerable ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.2:*:*:*:*:*:*:* Versions 2.2.2 Vulnerable ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_670_firmware:2.2.4:*:*:*:*:*:*:* Versions 2.2.4 Vulnerable ·Hitachi Energy
  • cpe:2.3:h:hitachienergy:relion_670:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.0:*:*:*:*:*:*:* Versions 2.2.0 Vulnerable ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.1:*:*:*:*:*:*:* Versions 2.2.1 Vulnerable ·Hitachi Energy
  • cpe:2.3:o:hitachienergy:relion_650_firmware:2.2.4:*:*:*:*:*:*:* Versions 2.2.4 Vulnerable ·Hitachi Energy
  • cpe:2.3:h:hitachienergy:relion_650:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
Show 2 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:*2.2.1VulnerableHitachi Energy
cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:*not specified by NVDRunning onHitachi Energy
  • cpe:2.3:o:hitachienergy:relion_sam600-io_firmware:2.2.1:*:*:*:*:*:*:* Versions 2.2.1 Vulnerable ·Hitachi Energy
  • cpe:2.3:h:hitachienergy:relion_sam600-io:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy

Remediation

  • Fix · CNA Relion 670 Series (Hitachi Energy) Fixed in 2.2.3.3

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-35535
  2. 2026-10-03 Alias added: GHSA-v26g-w7c2-rjj3

References

  • TI-2022-03099 IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products CVSS 3.1HIGH 7.5
  • TI-2021-08743 Specially Crafted IEC 61850 Protocol Sequence Vulnerability CVSS 3.1HIGH 7.5
  • TI-2019-13264 Improper input validation in Relion 650 and 670 Series CVSS 3.1HIGH 7.5
  • TI-2021-14265 Insufficient Security Control Vulnerability CVSS 3.1HIGH 7.2
  • TI-2023-04170 A vulnerability exists in the input validation of the GOOSE messages where out of range… CVSS 3.1HIGH 7.5
  • TI-2022-03542 Improper signature verification in Hitachi Energy Relion 670/650/SAM600-IO Series CVSS 3.1MEDIUM 4.5

Sources