Read the docs
TI-2020-11333 Aliases CVE-2020-14481GHSA-9h67-gqh5-w6f6

The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that…

Priority LOW 35CWE-261Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-326.

Summary

The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00163 5th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
RockwellFactoryTalk View SEup to 9.0; 10.0—No fix listedCNA
  • FactoryTalk View SE VendorRockwell Affected up to 9.0; 10.0 Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*up to 9.0VulnerableRockwell
cpe:2.3:a:rockwellautomation:factorytalk_view:10.0:*:*:*:se:*:*:*10.0VulnerableRockwell
  • cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:* Versions up to 9.0 Vulnerable ·Rockwell
  • cpe:2.3:a:rockwellautomation:factorytalk_view:10.0:*:*:*:se:*:*:* Versions 10.0 Vulnerable ·Rockwell

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2020-14481
  2. 2026-10-03 Alias added: GHSA-9h67-gqh5-w6f6

References

  • TI-2020-09688 Improper input validation in Rockwell FactoryTalk View SE CVSS 3.1CRITICAL 9.0
  • TI-2020-09687 Access control flaw in Rockwell FactoryTalk View SE CVSS 3.1HIGH 8.1
  • TI-2023-01947 FactoryTalk View Machine Edition Vulnerable to Remote Code Execution CVSS 3.1CRITICAL 9.8
  • TI-2020-09686 Information disclosure in Rockwell FactoryTalk View SE CVSS 3.1MEDIUM 4.3
  • TI-2024-04291 Rockwell Automation Datalog Function within in FactoryTalk® View SE contains SQL Injection Vulnerability CVSS 4.0HIGH 8.8
  • TI-2024-30786 FactoryTalk® View Site Edition Remote Code Execution Vulnerability via Lack of Input Validation CVSS 4.0CRITICAL 9.2
See all 17 →

Sources