Read the docs
TI-2021-06225 Aliases CVE-2021-23862GHSA-6226-9vg7-r4w4

Authenticated remote code execution in Bosch BVMS

Priority LOW 35CWE-20Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-78.

Summary

A crafted configuration packet sent by an authenticated administrative user can be used to execute arbitrary commands in system context. This issue also affects installations of the VRM, DIVAR IP, BVMS with VRM installed, the VIDEOJET decoder (VJD-7513 and VJD-8000).

Why it matters now

EPSS 0.0144 73rd percentileScored 2026-11-07
Fix Fixed BVMS (Bosch): 11.0.0, 10.0.2, 10.1.1

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
BoschBVMSup to 9.0.0; 11.0 to before 11.0.0; 10.0 to before 10.0.2; 10.1 to before 10.1.111.0.0, 10.0.2, 10.1.1Patch availableCNA
BoschDIVAR IP 7000 R2all—No fix listedCNA
BoschDIVAR IP all-in-one 5000all—No fix listedCNA
BoschDIVAR IP all-in-one 7000all—No fix listedCNA
BoschVRMup to 3.81; 4.0 – 4.00.0070; 3.83 – 3.83.0021; 3.82 – 3.82.0057—No fix listedCNA
BoschVJD-8000up to 10.01.0036—No fix listedCNA
BoschVJD-7513up to 10.22.0038—No fix listedCNA
  • BVMS VendorBosch Affected up to 9.0.0; 11.0 to before 11.0.0; 10.0 to before 10.0.2; 10.1 to before 10.1.1 Fixed in 11.0.0, 10.0.2, 10.1.1 Patch available CNA
  • DIVAR IP 7000 R2 VendorBosch Affected all Fixed in — No fix listed CNA
  • DIVAR IP all-in-one 5000 VendorBosch Affected all Fixed in — No fix listed CNA
  • DIVAR IP all-in-one 7000 VendorBosch Affected all Fixed in — No fix listed CNA
  • VRM VendorBosch Affected up to 3.81; 4.0 – 4.00.0070; 3.83 – 3.83.0021; 3.82 – 3.82.0057 Fixed in — No fix listed CNA
  • VJD-8000 VendorBosch Affected up to 10.01.0036 Fixed in — No fix listed CNA
  • VJD-7513 VendorBosch Affected up to 10.22.0038 Fixed in — No fix listed CNA

CPE configurations NVD · 10

CPEVersionsRoleVendor
cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*up to 9.0; 10.0 to before 10.0.2VulnerableBosch
cpe:2.3:a:bosch:bosch_video_management_system:10.1:*:*:*:*:*:*:*10.1VulnerableBosch
cpe:2.3:a:bosch:bosch_video_management_system:11.0:*:*:*:*:*:*:*11.0VulnerableBosch
cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:*up to 3.81; 3.82 – 3.82.0057; 3.83 – 3.83.0021; 4.0 – 4.00.0070VulnerableBosch
cpe:2.3:o:bosch:divar_ip_5000_firmware:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:o:bosch:divar_ip_7000_firmware:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:o:bosch:videojet_decoder_7513_firmware:*:*:*:*:*:*:*:*up to 10.22.0038VulnerableBosch
cpe:2.3:h:bosch:videojet_decoder_7513:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
cpe:2.3:o:bosch:videojet_decoder_8000_firmware:*:*:*:*:*:*:*:*up to 10.01.0036VulnerableBosch
cpe:2.3:h:bosch:videojet_decoder_8000:-:*:*:*:*:*:*:*not specified by NVDRunning onBosch
  • cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:* Versions up to 9.0; 10.0 to before 10.0.2 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:bosch_video_management_system:10.1:*:*:*:*:*:*:* Versions 10.1 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:bosch_video_management_system:11.0:*:*:*:*:*:*:* Versions 11.0 Vulnerable ·Bosch
  • cpe:2.3:a:bosch:video_recording_manager:*:*:*:*:*:*:*:* Versions up to 3.81; 3.82 – 3.82.0057; 3.83 – 3.83.0021; 4.0 – 4.00.0070 Vulnerable ·Bosch
  • cpe:2.3:o:bosch:divar_ip_5000_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:o:bosch:divar_ip_7000_firmware:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:o:bosch:videojet_decoder_7513_firmware:*:*:*:*:*:*:*:* Versions up to 10.22.0038 Vulnerable ·Bosch
  • cpe:2.3:h:bosch:videojet_decoder_7513:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch
  • cpe:2.3:o:bosch:videojet_decoder_8000_firmware:*:*:*:*:*:*:*:* Versions up to 10.01.0036 Vulnerable ·Bosch
  • cpe:2.3:h:bosch:videojet_decoder_8000:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Bosch

Remediation

  • Fix · CNA BVMS (Bosch) Fixed in 11.0.0, 10.0.2, 10.1.1

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Bosch BVMS 10.0.2, 10.1.1, 11.0.0

    4 records Highest priority Priority MEDIUM 1 MEDIUM, 3 LOW

    Other records, highest priority first

    • TI-2021-06222 Denial of Service and Authentication Bypass Vulnerability in multiple Bosch productsPriority MEDIUM 41
    • TI-2021-06224 Possible Access to Debug Functions in Bosch VRM / BVMSPriority LOW 30
    • TI-2021-06223 Reflected Cross Site Scripting (XSS) vulnerability in Bosch VRM / BVMSPriority LOW 28

Timeline

  1. 2026-10-02 Threatist record created from CVE-2021-23862
  2. 2026-10-03 Alias added: GHSA-6226-9vg7-r4w4

References

  • TI-2019-04894 Buffer Overflow for Bosch Video Systems, PSIM and Access Control Systems CVSS 3.1CRITICAL 9.8
  • TI-2019-04895 Improper Access Control for Bosch Video Systems, PSIM and Access Control Systems CVSS 3.1CRITICAL 9.1
  • TI-2021-06222 Denial of Service and Authentication Bypass Vulnerability in multiple Bosch products CVSS 3.1CRITICAL 9.1
  • TI-2021-06224 Possible Access to Debug Functions in Bosch VRM / BVMS CVSS 3.1MEDIUM 6.5
  • TI-2022-14173 Information disclosure in Bosch BVMS CVSS 3.1MEDIUM 5.9
  • TI-2021-06223 Reflected Cross Site Scripting (XSS) vulnerability in Bosch VRM / BVMS CVSS 3.1MEDIUM 6.1
See all 7 →

Sources