Read the docs
TI-2022-03746 Aliases CVE-2022-4098GHSA-9w34-3vc7-7786

Wiesemann & Theis: Multiple products prone to missing authentication through spoofing

Priority LOW 35CWE-290Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-290.

Summary

Multiple Wiesemann&Theis products of the ComServer Series are prone to an authentication bypass through IP spoofing. After a user logged in to the WBM of the Com-Server an unauthenticated attacker in the same subnet can obtain the session ID and through IP spoofing change arbitrary settings by crafting modified HTTP Get requests. This may result in a complete takeover of the device.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00346 28th percentileScored 2026-11-07
Fix Fixed Com-Server ++ (Wiesemann & Theis): 1.55Com-Server 20mA (Wiesemann & Theis): 1.55+14 more products

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Wiesemann & TheisCom-Server ++before 1.551.55Patch availableCNA
Wiesemann & TheisCom-Server 20mAbefore 1.551.55Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 100BaseFXbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 100BaseLXbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 19" 1Portbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed 19" 4Portbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Compactbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Industrybefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Isolatedbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed OEMbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Office 1 Portbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed Office 4 Portbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server Highspeed PoEbefore 1.781.78Patch availableCNA
Wiesemann & TheisCom-Server LCbefore 1.551.55Patch availableCNA
Wiesemann & TheisCom-Server PoE 3 x Isolatedbefore 1.551.55Patch availableCNA
Wiesemann & TheisCom-Server ULbefore 1.551.55Patch availableCNA
  • Com-Server ++ VendorWiesemann & Theis Affected before 1.55 Fixed in 1.55 Patch available CNA
  • Com-Server 20mA VendorWiesemann & Theis Affected before 1.55 Fixed in 1.55 Patch available CNA
  • Com-Server Highspeed 100BaseFX VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed 100BaseLX VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed 19" 1Port VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed 19" 4Port VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed Compact VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed Industry VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed Isolated VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed OEM VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed Office 1 Port VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed Office 4 Port VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server Highspeed PoE VendorWiesemann & Theis Affected before 1.78 Fixed in 1.78 Patch available CNA
  • Com-Server LC VendorWiesemann & Theis Affected before 1.55 Fixed in 1.55 Patch available CNA
  • Com-Server PoE 3 x Isolated VendorWiesemann & Theis Affected before 1.55 Fixed in 1.55 Patch available CNA
  • Com-Server UL VendorWiesemann & Theis Affected before 1.55 Fixed in 1.55 Patch available CNA

CPE configurations NVD · 32

CPEVersionsRoleVendor
cpe:2.3:o:wut:com-server_\+\+_firmware:*:*:*:*:*:*:*:*before 1.55VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_\+\+:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_20ma_firmware:*:*:*:*:*:*:*:*before 1.55VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_20ma:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_100basefx_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_100basefx:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_100baselx_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_100baselx:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_19\"_1port_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_19\"_1port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
  • cpe:2.3:o:wut:com-server_\+\+_firmware:*:*:*:*:*:*:*:* Versions before 1.55 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_\+\+:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_20ma_firmware:*:*:*:*:*:*:*:* Versions before 1.55 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_20ma:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_100basefx_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_100basefx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_100baselx_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_100baselx:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_19\"_1port_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_19\"_1port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
Show 22 more CPE
CPEVersionsRoleVendor
cpe:2.3:o:wut:com-server_highspeed_19\"_4port_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_19\"_4port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_compact_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_compact:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_industry_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_industry:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_isolated_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_isolated:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_oem_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_oem:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_office_1port_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_office_1port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_office_4port_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_office_4port:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_poe_firmware:*:*:*:*:*:*:*:*before 1.78VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_poe:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_lc_firmware:*:*:*:*:*:*:*:*before 1.55VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_lc:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_poe_3x_isolated_firmware:*:*:*:*:*:*:*:*before 1.55VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_poe_3x_isolated:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
cpe:2.3:o:wut:com-server_highspeed_ul_firmware:*:*:*:*:*:*:*:*before 1.55VulnerableWiesemann & Theis
cpe:2.3:h:wut:com-server_highspeed_ul:-:*:*:*:*:*:*:*not specified by NVDRunning onWiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_19\"_4port_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_19\"_4port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_compact_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_compact:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_industry_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_industry:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_isolated_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_isolated:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_oem_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_oem:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_office_1port_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_office_1port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_office_4port_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_office_4port:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_poe_firmware:*:*:*:*:*:*:*:* Versions before 1.78 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_poe:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_lc_firmware:*:*:*:*:*:*:*:* Versions before 1.55 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_lc:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_poe_3x_isolated_firmware:*:*:*:*:*:*:*:* Versions before 1.55 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_poe_3x_isolated:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis
  • cpe:2.3:o:wut:com-server_highspeed_ul_firmware:*:*:*:*:*:*:*:* Versions before 1.55 Vulnerable ·Wiesemann & Theis
  • cpe:2.3:h:wut:com-server_highspeed_ul:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Wiesemann & Theis

Remediation

  • Fix · CNA Com-Server ++ (Wiesemann & Theis) Fixed in 1.55
  • Fix · CNA Com-Server 20mA (Wiesemann & Theis) Fixed in 1.55
  • Fix · CNA Com-Server Highspeed 100BaseFX (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed 100BaseLX (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed 19" 1Port (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed 19" 4Port (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed Compact (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed Industry (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed Isolated (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed OEM (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed Office 1 Port (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed Office 4 Port (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server Highspeed PoE (Wiesemann & Theis) Fixed in 1.78
  • Fix · CNA Com-Server LC (Wiesemann & Theis) Fixed in 1.55
  • Fix · CNA Com-Server PoE 3 x Isolated (Wiesemann & Theis) Fixed in 1.55
  • Fix · CNA Com-Server UL (Wiesemann & Theis) Fixed in 1.55

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-4098
  2. 2026-10-03 Alias added: GHSA-9w34-3vc7-7786

References

  • TI-2022-20802 Wiesemann & Theis: Authentication bypass in Com-Server family CVSS 3.1CRITICAL 9.8
  • TI-2022-20804 Wiesemann & Theis: Small number space for allocating session id in Com-Server family CVSS 3.1HIGH 8.8
  • TI-2022-20803 Wiesemann & Theis: XSS vulnerability in web interface of the Com-Server family CVSS 3.1MEDIUM 5.4

Sources