Read the docs
TI-2022-08202 Aliases CVE-2022-24322GHSA-wwjr-j4cg-w355

Memory corruption in Schneider Electric EcoStruxure Control Expert

Priority LOW 27CWE-119Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
High
Impact type
—
Confidentiality · integrity · availability
None · High · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)

Why it matters now

EPSS 0.00644 51st percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure Control ExpertV15.0 SP1 and prior—No fix listedCNA
  • EcoStruxure Control Expert VendorSchneider Electric Affected V15.0 SP1 and prior Fixed in — No fix listed CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*before 15.0VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*15.0VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*15.0 sp1VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:* Versions before 15.0 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:* Versions 15.0 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:* Versions 15.0 sp1 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-24322
  2. 2026-10-03 Alias added: GHSA-wwjr-j4cg-w355
  3. 2026-10-21 EPSS moved to the 50th–90th percentile

References

  • TI-2021-05677 Path traversal in Schneider Electric EcoStruxure Control Expert CVSS 3.1HIGH 7.8
  • TI-2022-09848 A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs… CVSS 3.1CRITICAL 9.8
  • TI-2021-05659 Authentication bypass by spoofing in EcoStruxure Control Expert , EcoStruxure Control… CVSS 3.1CRITICAL 9.1
  • TI-2020-17142 Missing brute-force protection in PLC Simulator on EcoStruxureª Control Expert CVSS 3.1CRITICAL 9.8
  • TI-2022-22597 Authentication bypass by capture-replay in Schneider Electric EcoStruxure Control Expert CVSS 3.1CRITICAL 9.8
  • TI-2022-22596 Improper check for unusual conditions in Schneider Electric EcoStruxure Control Expert CVSS 3.1CRITICAL 9.8
See all 25 →

Sources