Read the docs

Schneider Electric

Records889All Threatist records
Exploited (KEV)1In CISA KEV
CVSS critical178CVSS 9.0–10.0
CVSS high452CVSS 7.0–8.9

Exploited now

Schneider Electric records in CISA KEV

Components

Products in the NVD configurations · select one to filter the records

Records

26 records in Ecostruxure Control Expert · all components

Priority MEDIUM 56

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution o…

CVSS 3.1HIGH 7.8 Local No auth User interaction EPSS 0.261 Published 2022-03-28 Fixed in V15.0 SP1, 2020 CWE-22
Priority MEDIUM 47

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Exper…

CVSS 3.1CRITICAL 9.1 Network No auth No interaction EPSS 0.01051 Published 2021-07-14 No fix listed CWE-290
Priority MEDIUM 47

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution whe…

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.02757 Published 2020-11-19 No fix listed CWE-307
Priority MEDIUM 45

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is l…

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.01173 Published 2023-01-30 No fix listed CWE-754
Priority MEDIUM 45

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity…

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.01581 Published 2020-03-23 No fix listed CWE-74
Priority MEDIUM 43

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus.

CVSS 3.1CRITICAL 9.8 Network No auth No interaction EPSS 0.00785 Published 2022-09-12 No fix listed CWE-640
Priority MEDIUM 40

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending special…

CVSS 3.1HIGH 8.8 Network Low privileges No interaction EPSS 0.01178 Published 2020-11-19 No fix listed CWE-494
Priority MEDIUM 40

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software…

CVSS 3.1HIGH 8.6 Local No auth User interaction EPSS 0.01447 Published 2020-12-11 No fix listed CWE-123
Priority LOW 37

CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when condu…

CVSS 3.1HIGH 8.1 Network No auth No interaction EPSS 0.00317 Published 2024-02-14 Fixed in v16.0, v2023 CWE-924
Priority LOW 37

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC si…

CVSS 3.1HIGH 7.5 Network No auth No interaction EPSS 0.01905 Published 2020-11-19 No fix listed CWE-120
Priority LOW 35

CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to a project file protected with application password when opening the file with EcoStruxure Control Expert.

CVSS 3.1HIGH 7.7 Local No auth No interaction EPSS 0.0023 Published 2024-02-14 Fixed in v16.0, v2023 CWE-798
Priority LOW 35

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in…

CVSS 3.1HIGH 7.5 Network No auth No interaction EPSS 0.01288 Published 2020-11-19 No fix listed CWE-754
Priority LOW 34

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause bypass of authentication when overwriting memory using a debugger.

CVSS 3.1HIGH 7.8 Local Low privileges No interaction EPSS 0.00327 Published 2020-11-19 No fix listed CWE-863
Priority LOW 31

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…

CVSS 3.1HIGH 7.1 Local Low privileges No interaction EPSS 0.00217 Published 2021-07-14 No fix listed CWE-522
Priority LOW 31

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…

CVSS 3.1HIGH 7.1 Local Low privileges No interaction EPSS 0.00216 Published 2021-07-14 No fix listed CWE-522
Priority LOW 30

CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering works…

CVSS 3.1HIGH 7.1 Local Low privileges No interaction EPSS 0.00149 Published 2024-02-14 Fixed in v16.0, v2023 CWE-522
Priority LOW 28

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to…

CVSS 3.1MEDIUM 5.9 Network No auth No interaction EPSS 0.0086 Published 2022-03-09 No fix listed CWE-754
Priority LOW 27

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an a…

CVSS 3.1MEDIUM 5.9 Network No auth No interaction EPSS 0.00644 Published 2022-03-09 No fix listed CWE-119
Priority LOW 24

A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert.

CVSS 3.1MEDIUM 5.5 Local Low privileges No interaction EPSS 0.00146 Published 2023-04-18 No fix listed CWE-269
Priority LOW 24

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened.

CVSS 3.1MEDIUM 5.5 Local No auth User interaction EPSS 0.00198 Published 2022-09-13 No fix listed CWE-119
Priority LOW 24

Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers…

CVSS 3.1MEDIUM 5.5 Local Low privileges No interaction EPSS 0.00109 Published 2021-07-14 No fix listed CWE-311