TI-2022-15359 Aliases CVE-2022-34465GHSA-c445-7759-935w

Out-of-bounds read in Siemens Parasolid V33.1

Priority LOW 36CWE-125Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.250), Parasolid V34.1 (All versions < V34.1.233), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15420)

Why it matters now

EPSS 0.01 63rd percentileScored 2026-11-07
Fix Fixed Parasolid V33.1 (Siemens): V33.1.264Parasolid V34.0 (Siemens): V34.0.250+3 more products

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensParasolid V33.1before V33.1.264V33.1.264Patch availableCNA
SiemensParasolid V34.0before V34.0.250V34.0.250Patch availableCNA
SiemensParasolid V34.1before V34.1.233V34.1.233Patch availableCNA
SiemensSimcenter Femap V2022.1before V2022.1.3V2022.1.3Patch availableCNA
SiemensSimcenter Femap V2022.2before V2022.2.2V2022.2.2Patch availableCNA
  • Parasolid V33.1 VendorSiemens Affected before V33.1.264 Fixed in V33.1.264 Patch available CNA
  • Parasolid V34.0 VendorSiemens Affected before V34.0.250 Fixed in V34.0.250 Patch available CNA
  • Parasolid V34.1 VendorSiemens Affected before V34.1.233 Fixed in V34.1.233 Patch available CNA
  • Simcenter Femap V2022.1 VendorSiemens Affected before V2022.1.3 Fixed in V2022.1.3 Patch available CNA
  • Simcenter Femap V2022.2 VendorSiemens Affected before V2022.2.2 Fixed in V2022.2.2 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*33.1 to before 33.1.264; after 34.0, before 34.0.250; after 34.1, before 34.1.233VulnerableSiemens
cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*2022.1.0 to before 2022.1.3; 2022.2.0 to before 2022.2.2VulnerableSiemens
  • cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* Versions 33.1 to before 33.1.264; after 34.0, before 34.0.250; after 34.1, before 34.1.233 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:* Versions 2022.1.0 to before 2022.1.3; 2022.2.0 to before 2022.2.2 Vulnerable ·Siemens

Remediation

  • Fix · CNA Parasolid V33.1 (Siemens) Fixed in V33.1.264
  • Fix · CNA Parasolid V34.0 (Siemens) Fixed in V34.0.250
  • Fix · CNA Parasolid V34.1 (Siemens) Fixed in V34.1.233
  • Fix · CNA Simcenter Femap V2022.1 (Siemens) Fixed in V2022.1.3
  • Fix · CNA Simcenter Femap V2022.2 (Siemens) Fixed in V2022.2.2

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-34465
  2. 2026-10-03 Alias added: GHSA-c445-7759-935w

References

  • TI-2022-22893 Out-of-bounds read in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
  • TI-2022-22891 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
  • TI-2024-21079 Out-of-bounds write in Siemens Parasolid V35.1 CVSS 3.1HIGH 7.8
  • TI-2023-24404 Stack-based buffer overflow in Siemens Parasolid V35.0 CVSS 3.1HIGH 7.8
  • TI-2023-21659 Out-of-bounds write in Siemens Parasolid V34.1 CVSS 3.1HIGH 7.8
  • TI-2022-22892 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
See all 51 →

Sources