Read the docs
TI-2022-17385 Aliases CVE-2022-37302GHSA-mp38-wwj7-h8qj

Memory corruption in Schneider Electric EcoStruxure Control Expert

Priority LOW 24CWE-119Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Denial of service
Confidentiality · integrity · availability
None · None · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-119 and the CVSS impact.

Summary

A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).

Why it matters now

EPSS 0.00198 9th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

Not available: CISA has not published SSVC decision points for this record.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure Control ExpertHF001 – 15.1—No fix listedCNA
  • EcoStruxure Control Expert VendorSchneider Electric Affected HF001 – 15.1 Fixed in — No fix listed CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*before 15.1VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:*15.1VulnerableSchneider Electric
cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:hf001:*:*:*:*:*:*15.1 hf001VulnerableSchneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:* Versions before 15.1 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:-:*:*:*:*:*:* Versions 15.1 Vulnerable ·Schneider Electric
  • cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.1:hf001:*:*:*:*:*:* Versions 15.1 hf001 Vulnerable ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2022-37302
  2. 2026-10-03 Alias added: GHSA-mp38-wwj7-h8qj

References

  • TI-2021-05677 Path traversal in Schneider Electric EcoStruxure Control Expert CVSS 3.1HIGH 7.8
  • TI-2022-09848 A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs… CVSS 3.1CRITICAL 9.8
  • TI-2021-05659 Authentication bypass by spoofing in EcoStruxure Control Expert , EcoStruxure Control… CVSS 3.1CRITICAL 9.1
  • TI-2020-17142 Missing brute-force protection in PLC Simulator on EcoStruxureª Control Expert CVSS 3.1CRITICAL 9.8
  • TI-2022-22597 Authentication bypass by capture-replay in Schneider Electric EcoStruxure Control Expert CVSS 3.1CRITICAL 9.8
  • TI-2022-22596 Improper check for unusual conditions in Schneider Electric EcoStruxure Control Expert CVSS 3.1CRITICAL 9.8
See all 25 →

Sources