Out-of-bounds write in Siemens Parasolid V34.0
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 | before V34.0.252 | V34.0.252 | Patch available | CNA |
| Siemens | Parasolid V34.1 | before V34.1.242 | V34.1.242 | Patch available | CNA |
| Siemens | Parasolid V35.0 | before V35.0.170 | V35.0.170 | Patch available | CNA |
| Siemens | Simcenter Femap | before V2023.1 | V2023.1 | Patch available | CNA |
- Parasolid V34.0 VendorSiemens Affected before V34.0.252 Fixed in V34.0.252 Patch available CNA
- Parasolid V34.1 VendorSiemens Affected before V34.1.242 Fixed in V34.1.242 Patch available CNA
- Parasolid V35.0 VendorSiemens Affected before V35.0.170 Fixed in V35.0.170 Patch available CNA
- Simcenter Femap VendorSiemens Affected before V2023.1 Fixed in V2023.1 Patch available CNA
CPE configurations NVD · 1
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* | 34.0 to before 34.0.252; 34.1 to before 34.1.242; 35.0 to before 35.0.170 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* Versions 34.0 to before 34.0.252; 34.1 to before 34.1.242; 35.0 to before 35.0.170 Vulnerable ·Siemens
Remediation
- Fix · CNA Parasolid V34.0 (Siemens) Fixed in V34.0.252
- Fix · CNA Parasolid V34.1 (Siemens) Fixed in V34.1.242
- Fix · CNA Parasolid V35.0 (Siemens) Fixed in V35.0.170
- Fix · CNA Simcenter Femap (Siemens) Fixed in V2023.1
Timeline
- 2026-10-02 Threatist record created from CVE-2022-43397
- 2026-10-03 Alias added: GHSA-fvjh-rh68-qmhg
References
More Siemens Parasolid vulnerabilities
- TI-2022-22893 Out-of-bounds read in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2022-22891 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2024-21079 Out-of-bounds write in Siemens Parasolid V35.1 CVSS 3.1HIGH 7.8
- TI-2023-24404 Stack-based buffer overflow in Siemens Parasolid V35.0 CVSS 3.1HIGH 7.8
- TI-2023-21659 Out-of-bounds write in Siemens Parasolid V34.1 CVSS 3.1HIGH 7.8
- TI-2022-22892 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
Sources
- CVE-2022-43397 · CVE Program
- CVE-2022-43397 · NVD
- FIRST EPSS
- GHSA-fvjh-rh68-qmhg · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences