Cross-site scripting in Hitachi Energy RTU500 series
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Cross-site scripting
- Confidentiality · integrity · availability
- Low · Low · None
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-79.
Summary
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again.
Why it matters now
SSVC decision points
Not available: CISA has not published SSVC decision points for this record.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Hitachi Energy | RTU500 series | RTU500 series CMU Firmware version 12.0.1 – 12.0.14; RTU500 series CMU Firmware version 12.2.1 – 12.2.11; RTU500 series CMU Firmware version 12.4.1 – 12.4.11 ; RTU500 series CMU Firmware version 12.6.1 – 12.6.9 ; RTU500 series CMU Firmware version 12.7.1 – 12.7.6; RTU500 series CMU Firmware version 13.2.1 – 13.2.6 ; RTU500 series CMU Firmware version 13.4.1 – 13.4.3 | — | No fix listed | CNA |
- RTU500 series VendorHitachi Energy Affected RTU500 series CMU Firmware version 12.0.1 – 12.0.14; RTU500 series CMU Firmware version 12.2.1 – 12.2.11; RTU500 series CMU Firmware version 12.4.1 – 12.4.11 ; RTU500 series CMU Firmware version 12.6.1 – 12.6.9 ; RTU500 series CMU Firmware version 12.7.1 – 12.7.6; RTU500 series CMU Firmware version 13.2.1 – 13.2.6 ; RTU500 series CMU Firmware version 13.4.1 – 13.4.3 Fixed in — No fix listed CNA
CPE configurations NVD · 8
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:* | 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 | Vulnerable | Hitachi Energy |
| cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Hitachi Energy |
| cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:* | 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 | Vulnerable | Hitachi Energy |
| cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Hitachi Energy |
| cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:* | 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 | Vulnerable | Hitachi Energy |
| cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Hitachi Energy |
| cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:* | 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 | Vulnerable | Hitachi Energy |
| cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Hitachi Energy |
- cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:* Versions 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 Vulnerable ·Hitachi Energy
- cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
- cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:* Versions 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 Vulnerable ·Hitachi Energy
- cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
- cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:* Versions 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 Vulnerable ·Hitachi Energy
- cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
- cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:* Versions 12.0.1 – 12.0.14; 12.2.1 – 12.2.11; 12.4.1 – 12.4.11; 12.6.1 – 12.6.9; 12.7.1 – 12.7.6; 13.2.1 – 13.2.6; 13.4.1 – 13.4.3 Vulnerable ·Hitachi Energy
- cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Hitachi Energy
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2023-5768
- 2026-10-03 Alias added: GHSA-gv34-7cg2-7vfg
References
More Hitachi Energy Rtu520 Firmware vulnerabilities
- TI-2026-01456 IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of… CVSS 4.0HIGH 8.7
- TI-2022-01926 Out-of-bounds write in Hitachi Energy RTU500 series CMU firmware CVSS 3.1HIGH 7.5
- TI-2023-05307 Cross-site scripting in Hitachi Energy RTU500 CVSS 3.1MEDIUM 6.1
- TI-2023-05305 Cross-site scripting in Hitachi Energy RTU500 CVSS 3.1MEDIUM 6.1
- TI-2026-01455 RTU500 web interface: An unprivileged user can read user management information. CVSS 4.0MEDIUM 5.3
Sources
- CVE-2023-5768 · CVE Program
- CVE-2023-5768 · NVD
- FIRST EPSS
- GHSA-gv34-7cg2-7vfg · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences