Out-of-bounds read in Siemens Parasolid V34.1
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Passive
- Attack complexity
- High
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Parasolid V34.1 | before V34.1.258 | V34.1.258 | Patch available | CNA |
| Siemens | Parasolid V35.0 | before V35.0.254 | V35.0.254 | Patch available | CNA |
| Siemens | Parasolid V35.1 | before V35.1.184 | V35.1.184 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.1 | all versions | — | No fix listed | CNA |
| Siemens | Teamcenter Visualization V14.2 | before V14.2.0.12 | V14.2.0.12 | Patch available | CNA |
| Siemens | Teamcenter Visualization V14.3 | before V14.3.0.9 | V14.3.0.9 | Patch available | CNA |
| Siemens | Teamcenter Visualization V2312 | before V2312.0004 | V2312.0004 | Patch available | CNA |
- Parasolid V34.1 VendorSiemens Affected before V34.1.258 Fixed in V34.1.258 Patch available CNA
- Parasolid V35.0 VendorSiemens Affected before V35.0.254 Fixed in V35.0.254 Patch available CNA
- Parasolid V35.1 VendorSiemens Affected before V35.1.184 Fixed in V35.1.184 Patch available CNA
- Teamcenter Visualization V14.1 VendorSiemens Affected all versions Fixed in — No fix listed CNA
- Teamcenter Visualization V14.2 VendorSiemens Affected before V14.2.0.12 Fixed in V14.2.0.12 Patch available CNA
- Teamcenter Visualization V14.3 VendorSiemens Affected before V14.3.0.9 Fixed in V14.3.0.9 Patch available CNA
- Teamcenter Visualization V2312 VendorSiemens Affected before V2312.0004 Fixed in V2312.0004 Patch available CNA
CPE configurations NVD · 2
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* | 34.1 to before 34.1.258; 35.0 to before 35.0.254; 35.1 to before 35.1.184 | Vulnerable | Siemens |
| cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* | 14.1 to before 14.1.0.11; 14.2 to before 14.2.0.6; 14.3 to before 14.3.0.3 | Vulnerable | Siemens |
- cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:* Versions 34.1 to before 34.1.258; 35.0 to before 35.0.254; 35.1 to before 35.1.184 Vulnerable ·Siemens
- cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* Versions 14.1 to before 14.1.0.11; 14.2 to before 14.2.0.6; 14.3 to before 14.3.0.3 Vulnerable ·Siemens
Remediation
- Fix · CNA Parasolid V34.1 (Siemens) Fixed in V34.1.258
- Fix · CNA Parasolid V35.0 (Siemens) Fixed in V35.0.254
- Fix · CNA Parasolid V35.1 (Siemens) Fixed in V35.1.184
- Fix · CNA Teamcenter Visualization V14.2 (Siemens) Fixed in V14.2.0.12
- Fix · CNA Teamcenter Visualization V14.3 (Siemens) Fixed in V14.3.0.9
- Fix · CNA Teamcenter Visualization V2312 (Siemens) Fixed in V2312.0004
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Parasolid V34.1, Parasolid V35.0 V34.1.258, V35.0.254
9 records Highest priority Priority LOW 9 LOW
Other records, highest priority first
- TI-2023-19910 Out-of-bounds read in Siemens Parasolid V34.1Priority LOW 33
- TI-2023-19908 Out-of-bounds write in Siemens Parasolid V34.1Priority LOW 33
- TI-2023-19907 Out-of-bounds read in Siemens Parasolid V34.1Priority LOW 33
- Release ·
Siemens Parasolid V35.1 V35.1.184
3 records Highest priority Priority LOW 3 LOW
Other records, highest priority first
- TI-2023-19908 Out-of-bounds write in Siemens Parasolid V34.1Priority LOW 33
- TI-2023-19911 Out-of-bounds read in Siemens Parasolid V34.1Priority LOW 31
Show 1 more group
- Release ·
Siemens Teamcenter Visualization V14.2, Teamcenter Visualization V14.3, Teamcenter Visualization V2312 V14.2.0.12, V14.3.0.9, V2312.0004
3 records Highest priority Priority LOW 3 LOW
Other records, highest priority first
- TI-2023-19907 Out-of-bounds read in Siemens Parasolid V34.1Priority LOW 33
- TI-2023-19911 Out-of-bounds read in Siemens Parasolid V34.1Priority LOW 31
Timeline
- 2026-10-02 Threatist record created from CVE-2023-38529
- 2026-10-03 Alias added: GHSA-85h8-9x77-pg3v
References
More Siemens Parasolid vulnerabilities
- TI-2022-22893 Out-of-bounds read in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2022-22891 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
- TI-2024-21079 Out-of-bounds write in Siemens Parasolid V35.1 CVSS 3.1HIGH 7.8
- TI-2023-24404 Stack-based buffer overflow in Siemens Parasolid V35.0 CVSS 3.1HIGH 7.8
- TI-2023-21659 Out-of-bounds write in Siemens Parasolid V34.1 CVSS 3.1HIGH 7.8
- TI-2022-22892 Out-of-bounds write in Siemens Parasolid V33.1 CVSS 3.1HIGH 7.8
Sources
- CVE-2023-38529 · CVE Program
- CVE-2023-38529 · NVD
- FIRST EPSS
- GHSA-85h8-9x77-pg3v · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences