Read the docs
TI-2023-20600 Aliases CVE-2023-39468GHSA-4p7j-rqc6-ff4w

Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous…

Priority LOW 37CWE-749Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.0 · CNA. Fix status from CNA.

Summary

Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.01878 79th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Triangle MicroWorksSCADA Data Gateway5.1.3.20324—No fix listedCNA
  • SCADA Data Gateway VendorTriangle MicroWorks Affected 5.1.3.20324 Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*5.1.3.20324VulnerableTriangle MicroWorks
  • cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:* Versions 5.1.3.20324 Vulnerable ·Triangle MicroWorks

Remediation

No fixed version listed by the sources yet.

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    Triangle MicroWorks SCADA Data Gateway — vendor-provided URL

    12 records Highest priority Priority MEDIUM 2 MEDIUM, 10 LOW

    Other records, highest priority first

    • TI-2023-20589 Missing authentication in Triangle MicroWorks SCADA Data GatewayPriority MEDIUM 47
    • TI-2023-20597 Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information…Priority MEDIUM 40
    • TI-2023-20596 Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote…Priority LOW 38

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-39468
  2. 2026-10-03 Alias added: GHSA-4p7j-rqc6-ff4w

References

  • TI-2020-08523 Type confusion in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122… CVSS 3.1CRITICAL 9.8
  • TI-2023-02050 On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated… CVSS 3.1CRITICAL 9.8
  • TI-2023-20589 Missing authentication in Triangle MicroWorks SCADA Data Gateway CVSS 3.0CRITICAL 9.8
  • TI-2022-00294 Path traversal in Triangle MicroWorks SCADA Data Gateway CVSS 3.1HIGH 8.8
  • TI-2023-20597 Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information… CVSS 3.0HIGH 7.5
  • TI-2023-20596 Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote… CVSS 3.0HIGH 7.2
See all 21 →

Sources