TI-2023-24215 Aliases CVE-2023-45204GHSA-56j9-j8r9-6q32

Incorrect type conversion in Siemens Tecnomatix Plant Simulation V2201

Priority LOW 36CWE-704Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-704 and the CVSS impact.

Summary

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a type confusion vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21268)

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00245 15th percentileScored 2026-11-07
Fix Fixed Tecnomatix Plant Simulation V2201 (Siemens): V2201.0009Tecnomatix Plant Simulation V2302 (Siemens): V2302.0003

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensTecnomatix Plant Simulation V2201before V2201.0009V2201.0009Patch availableCNA
SiemensTecnomatix Plant Simulation V2302before V2302.0003V2302.0003Patch availableCNA
  • Tecnomatix Plant Simulation V2201 VendorSiemens Affected before V2201.0009 Fixed in V2201.0009 Patch available CNA
  • Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0003 Fixed in V2302.0003 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*2201 to before 2201.0009; 2302 to before 2302.0003VulnerableSiemens
  • cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:* Versions 2201 to before 2201.0009; 2302 to before 2302.0003 Vulnerable ·Siemens

Remediation

  • Fix · CNA Tecnomatix Plant Simulation V2201 (Siemens) Fixed in V2201.0009
  • Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0003

Timeline

  1. 2026-10-02 Threatist record created from CVE-2023-45204
  2. 2026-10-03 Alias added: GHSA-56j9-j8r9-6q32

References

  • TI-2023-24404 Stack-based buffer overflow in Siemens Parasolid V35.0 CVSS 3.1HIGH 7.8
  • TI-2023-23638 Out-of-bounds read in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
  • TI-2023-23637 Out-of-bounds read in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
  • TI-2023-23636 Out-of-bounds read in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
  • TI-2023-23635 Out-of-bounds read in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
  • TI-2023-23634 Out-of-bounds write in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
See all 18 →