Path traversal in Honeywell Saia PG5 Controls Suite
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- No fix listed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA.
Summary
Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of ZIP files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user. . Was ZDI-CAN-18412.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Honeywell | Saia PG5 Controls Suite | PG5 v2.3.193 | — | No fix listed | CNA |
- Saia PG5 Controls Suite VendorHoneywell Affected PG5 v2.3.193 Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2023-51599
- 2026-10-03 Alias added: GHSA-44j3-q6p8-p422
References
Advisory 1
More Honeywell Saia Pg5 Controls Suite vulnerabilities
- TI-2023-28253 XML external entity injection in Honeywell Saia PG5 Controls Suite CVSS 3.1MEDIUM 6.5
- TI-2023-28255 Path traversal in Honeywell Saia PG5 Controls Suite CVSS 3.1HIGH 8.8
- TI-2022-12554 Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. CVSS 3.1HIGH 8.1
- TI-2023-28257 XML external entity injection in Honeywell Saia PG5 Controls Suite CVSS 3.1MEDIUM 6.5
- TI-2023-28256 XML external entity injection in Honeywell Saia PG5 Controls Suite CVSS 3.1MEDIUM 6.5
- TI-2023-28254 XML external entity injection in Honeywell Saia PG5 Controls Suite CVSS 3.1MEDIUM 6.5