Read the docs
TI-2024-01908 Aliases CVE-2024-2052GHSA-p833-v842-wj4m

CWE-552: Files or Directories Accessible to External Parties vulnerability exists that…

Priority LOW 39CWE-552Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-552.

Summary

CWE-552: Files or Directories Accessible to External Parties vulnerability exists that could allow unauthenticated files and logs exfiltration and download of files when an attacker modifies the URL to download to a different location.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00513 43rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEasergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H SC2-04MOD-07000104 – prior—No fix listedCNA
Schneider ElectricEasergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200HSC2-04IEC-07000104 – prior—No fix listedCNA
Schneider ElectricEasergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200HSC2-04DNP-07000104 – prior—No fix listedCNA
  • Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H VendorSchneider Electric Affected SC2-04MOD-07000104 – prior Fixed in — No fix listed CNA
  • Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200H VendorSchneider Electric Affected SC2-04IEC-07000104 – prior Fixed in — No fix listed CNA
  • Easergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200H VendorSchneider Electric Affected SC2-04DNP-07000104 – prior Fixed in — No fix listed CNA

CPE names CISA-ADP · 5

CPEVersionsRoleVendor
cpe:2.3:h:schneider-electric:t200h:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
cpe:2.3:h:schneider-electric:t200s:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
cpe:2.3:h:schneider-electric:t200p:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
cpe:2.3:h:schneider-electric:t200e:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
cpe:2.3:h:schneider-electric:t200i:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
  • cpe:2.3:h:schneider-electric:t200h:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric
  • cpe:2.3:h:schneider-electric:t200s:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric
  • cpe:2.3:h:schneider-electric:t200p:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric
  • cpe:2.3:h:schneider-electric:t200e:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric
  • cpe:2.3:h:schneider-electric:t200i:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-2052
  2. 2026-10-03 Alias added: GHSA-p833-v842-wj4m

References

  • TI-2018-05679 SQL injection in U.motion Builder software version 1.3.4 KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2022-15561 OS command injection in Schneider Electric SpaceLogic C-Bus Home Controller CVSS 3.1HIGH 8.8
  • TI-2023-04970 Path traversal in Schneider Electric C-Bus Toolkit CVSS 3.1CRITICAL 9.8
  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
See all 888 →