Read the docs
TI-2024-05696 Aliases CVE-2024-6147GHSA-mpmm-q7jf-hx4p

Link following in Poly Plantronics Hub

Priority LOW 36CWE-59Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · NVD. Fix status from CNA.

Summary

Poly Plantronics Hub Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Poly Plantronics Hub. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability. The specific flaw exists within the Spokes Update Service. By creating a symbolic link, an attacker can abuse the service to delete a file. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-18271.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00389 33rd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
PolyPlantronics Hub3.24.2 Build 36336—No fix listedCNA
  • Plantronics Hub VendorPoly Affected 3.24.2 Build 36336 Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:hp:poly_plantronics_hub:3.24.2:*:*:*:*:*:*:*3.24.2VulnerableHewlett Packard Enterprise

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-6147
  2. 2026-10-03 Alias added: GHSA-mpmm-q7jf-hx4p

References

Advisory 1

  • TI-2022-09828 An issue was discovered in Poly EagleEye Director II before 2.2.2.1. CVSS 3.1HIGH 7.2
  • TI-2022-09826 An issue was discovered in Poly EagleEye Director II before 2.2.2.1. CVSS 3.1CRITICAL 9.8
  • TI-2018-12709 A remote code execution issue in the ping command on Poly Trio 8800 5.7.1.4145 devices… CVSS 3.1HIGH 8.8
  • TI-2022-09827 An issue was discovered in Poly Studio before 3.7.0. CVSS 3.1HIGH 8.8
  • TI-2023-04121 Poly VVX 601 Diagnostic Telnet Mode os command injection CVSS 3.1HIGH 7.2
  • TI-2021-15211 A command-injection vulnerability in an authenticated Telnet connection in Poly (formerly… CVSS 3.1HIGH 7.2
See all 13 →