Read the docs
TI-2024-08295 Aliases CVE-2024-8935GHSA-6rch-pvx5-r93q

Authentication bypass by spoofing in Schneider Electric Modicon M340 CPU

Priority LOW 36CWE-290Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
Passive
Attack complexity
High
Attack requirements
Present
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-290.

Summary

CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause a denial of service and loss of confidentiality and integrity of controllers when conducting a Man-In-The-Middle attack between the controller and the engineering workstation while a valid user is establishing a communication session. This vulnerability is inherent to Diffie Hellman algorithm which does not protect against Man-In-The-Middle attacks.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00522 44th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricModicon M340 CPU (part numbers BMXP34*)All versions since SV3.60—No fix listedCNA
Schneider ElectricModicon MC80 (part numbers BMKC80)All versions—No fix listedCNA
Schneider ElectricModicon Momentum Unity M1E Processor (171CBU*)All Versions—No fix listedCNA
  • Modicon M340 CPU (part numbers BMXP34*) VendorSchneider Electric Affected All versions since SV3.60 Fixed in — No fix listed CNA
  • Modicon MC80 (part numbers BMKC80) VendorSchneider Electric Affected All versions Fixed in — No fix listed CNA
  • Modicon Momentum Unity M1E Processor (171CBU*) VendorSchneider Electric Affected All Versions Fixed in — No fix listed CNA

CPE names CISA-ADP · 3

CPEVersionsRoleVendor
cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
cpe:2.3:h:schneider-electric:modicon_mc80_bmkc8020301:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:*not specified by CISA-ADP—Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_mc80_bmkc8020301:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric
  • cpe:2.3:h:schneider-electric:modicon_momentum_unity_m1e_processor:-:*:*:*:*:*:*:* Versions not specified by CISA-ADP — ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-8935
  2. 2026-10-03 Alias added: GHSA-6rch-pvx5-r93q

References

  • TI-2018-05679 SQL injection in U.motion Builder software version 1.3.4 KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2022-15561 OS command injection in Schneider Electric SpaceLogic C-Bus Home Controller CVSS 3.1HIGH 8.8
  • TI-2023-04970 Path traversal in Schneider Electric C-Bus Toolkit CVSS 3.1CRITICAL 9.8
  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
See all 888 →