PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Impact type
- Security bypass
- Confidentiality · integrity · availability
- High · High · None
- Fix status
- Fixed
Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-306.
Summary
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Active
- Automatable
- Yes
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| PTZOptics | PT30X-SDI | before 6.3.40 | 6.3.40 | Patch available | CNA |
| PTZOptics | PT30X-NDI | before 6.3.40 | 6.3.40 | Patch available | CNA |
- PT30X-SDI VendorPTZOptics Affected before 6.3.40 Fixed in 6.3.40 Patch available CNA
- PT30X-NDI VendorPTZOptics Affected before 6.3.40 Fixed in 6.3.40 Patch available CNA
CPE configurations NVD · 4
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* | before 6.3.40 | Vulnerable | PTZOptics |
| cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:* | not specified by NVD | Running on | PTZOptics |
| cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:* | before 6.3.40 | Vulnerable | PTZOptics |
| cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:* | not specified by NVD | Running on | PTZOptics |
- cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* Versions before 6.3.40 Vulnerable ·PTZOptics
- cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·PTZOptics
- cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:* Versions before 6.3.40 Vulnerable ·PTZOptics
- cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·PTZOptics
Remediation
- Fix · CNA PT30X-SDI (PTZOptics) Fixed in 6.3.40
- Fix · CNA PT30X-NDI (PTZOptics) Fixed in 6.3.40
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Advisory ·
PTZOptics PT30X-NDI, PT30X-SDI — ptzoptics.com/firmware-changelog
2 records Highest priority Priority CRITICAL 2 CRITICAL
Other records, highest priority first
- TI-2024-08317 PTZOptics NDI and SDI Cameras Command Injection via NTP Address ConfigurationPriority CRITICAL 91
Timeline
- 2024-11-04 Added to CISA KEV
- 2026-10-02 Threatist record created from CVE-2024-8956
- 2026-10-03 Alias added: GHSA-58rw-8pf6-2mgq
References
More PTZOptics Pt30x-ndi-xx-g2 Firmware vulnerabilities
- TI-2024-08317 PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration KEVCVSS 3.1HIGH 7.2
Sources
- CVE-2024-8956 · CVE Program
- CVE-2024-8956 · NVD
- CISA Known Exploited Vulnerabilities
- FIRST EPSS
- GHSA-58rw-8pf6-2mgq · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences