Read the docs
TI-2024-08317 Aliases CVE-2024-8957GHSA-9cx9-7v8g-h36v

PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration

Priority CRITICAL 91Exploited in the wildCWE-78Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-78.

Summary

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

Why it matters now

Exploitation Active In CISA KEV since 2024-11-04CISA due date 2024-11-25
EPSS 0.7984 99th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix Fixed PT30X-SDI (PTZOptics): 6.3.40PT30X-NDI (PTZOptics): 6.3.40

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
Active
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
PTZOpticsPT30X-SDIbefore 6.3.406.3.40Patch availableCNA
PTZOpticsPT30X-NDIbefore 6.3.406.3.40Patch availableCNA
  • PT30X-SDI VendorPTZOptics Affected before 6.3.40 Fixed in 6.3.40 Patch available CNA
  • PT30X-NDI VendorPTZOptics Affected before 6.3.40 Fixed in 6.3.40 Patch available CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:*before 6.3.40VulnerablePTZOptics
cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:*not specified by NVDRunning onPTZOptics
cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:*before 6.3.40VulnerablePTZOptics
cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:*not specified by NVDRunning onPTZOptics
  • cpe:2.3:o:ptzoptics:pt30x-sdi_firmware:*:*:*:*:*:*:*:* Versions before 6.3.40 Vulnerable ·PTZOptics
  • cpe:2.3:h:ptzoptics:pt30x-sdi:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·PTZOptics
  • cpe:2.3:o:ptzoptics:pt30x-ndi-xx-g2_firmware:*:*:*:*:*:*:*:* Versions before 6.3.40 Vulnerable ·PTZOptics
  • cpe:2.3:h:ptzoptics:pt30x-ndi-xx-g2:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·PTZOptics

Remediation

  • Fix · CNA PT30X-SDI (PTZOptics) Fixed in 6.3.40
  • Fix · CNA PT30X-NDI (PTZOptics) Fixed in 6.3.40

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Advisory ·

    PTZOptics PT30X-NDI, PT30X-SDI — ptzoptics.com/firmware-changelog

    2 records Highest priority Priority CRITICAL 2 CRITICAL

    Other records, highest priority first

    • TI-2024-08316 PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient AuthenticationPriority CRITICAL 98

Timeline

  1. 2024-11-04 Added to CISA KEV
  2. 2026-10-02 Threatist record created from CVE-2024-8957
  3. 2026-10-03 Alias added: GHSA-9cx9-7v8g-h36v

References

  • TI-2024-08316 PTZOptics NDI and SDI Cameras /cgi-bin/param.cgi Insufficient Authentication KEVCVSS 3.1CRITICAL 9.1

Sources