Read the docs
TI-2024-08363 Aliases CVE-2024-9005GHSA-h25j-66v8-m35v

Deserialization of untrusted data in Schneider Electric EcoStruxure Power Monitoring…

Priority MEDIUM 40CWE-502Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
Active
Attack complexity
High
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-502.

Summary

CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be remotely executed on the server when unsafely deserialized data is posted to the web server.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00342 27th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure Power Monitoring Expert (PME)up to 2022—No fix listedCNA
  • EcoStruxure Power Monitoring Expert (PME) VendorSchneider Electric Affected up to 2022 Fixed in — No fix listed CNA

CPE names CISA-ADP · 1

CPEVersionsRoleVendor
cpe:2.3:a:schneider_electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*——Schneider Electric
  • cpe:2.3:a:schneider_electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:* Versions — — ·Schneider Electric

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-9005
  2. 2026-10-03 Alias added: GHSA-h25j-66v8-m35v

References

  • TI-2018-05679 SQL injection in U.motion Builder software version 1.3.4 KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2022-15561 OS command injection in Schneider Electric SpaceLogic C-Bus Home Controller CVSS 3.1HIGH 8.8
  • TI-2023-04970 Path traversal in Schneider Electric C-Bus Toolkit CVSS 3.1CRITICAL 9.8
  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
See all 888 →