NULL pointer dereference in Siemens Tecnomatix Plant Simulation V2201
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- Required
- Attack complexity
- Low
- Impact type
- Denial of service
- Confidentiality · integrity · availability
- None · None · High
- Fix status
- Fixed
Attack profile from CVSS 3.1 · NVD. Fix status from CNA. Impact type from CWE-476.
Summary
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted SPP files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2201 | all versions | — | No fix listed | CNA |
| Siemens | Tecnomatix Plant Simulation V2302 | before V2302.0007 | V2302.0007 | Patch available | CNA |
Remediation
- Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0007
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Tecnomatix Plant Simulation V2302 V2302.0007
4 records Highest priority Priority LOW 4 LOW
Other records, highest priority first
- TI-2024-15797 Out-of-bounds write in Siemens Tecnomatix Plant Simulation V2201Priority LOW 35
- TI-2024-15795 NULL pointer dereference in Siemens Tecnomatix Plant Simulation V2201Priority LOW 24
- TI-2024-15793 NULL pointer dereference in Siemens Tecnomatix Plant Simulation V2201Priority LOW 24
Timeline
- 2026-10-02 Threatist record created from CVE-2024-23800
- 2026-10-03 Alias added: GHSA-pq7f-896m-7jg7
References
More Siemens Tecnomatix Plant Simulation vulnerabilities
- TI-2023-12136 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2021-08891 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2021-08890 Memory corruption in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2021-08889 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
- TI-2024-15792 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
- TI-2024-15791 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
Sources
- CVE-2024-23800 · CVE Program
- CVE-2024-23800 · NVD
- FIRST EPSS
- GHSA-pq7f-896m-7jg7 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences