Read the docs
TI-2024-15797 Aliases CVE-2024-23803GHSA-2569-97m4-w479

Out-of-bounds write in Siemens Tecnomatix Plant Simulation V2201

Priority LOW 35CWE-787Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Required
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-787 and the CVSS impact.

Summary

A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions), Tecnomatix Plant Simulation V2302 (All versions < V2302.0007). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00206 10th percentileScored 2026-11-07
Fix Fixed Tecnomatix Plant Simulation V2302 (Siemens): V2302.0007

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensTecnomatix Plant Simulation V2201all versions—No fix listedCNA
SiemensTecnomatix Plant Simulation V2302before V2302.0007V2302.0007Patch availableCNA
  • Tecnomatix Plant Simulation V2201 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Tecnomatix Plant Simulation V2302 VendorSiemens Affected before V2302.0007 Fixed in V2302.0007 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*2302.0 to before 2302.0007VulnerableSiemens
cpe:2.3:a:siemens:tecnomatix_plant_simulation:2201.0:-:*:*:*:*:*:*2201.0VulnerableSiemens
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* Versions 2302.0 to before 2302.0007 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:tecnomatix_plant_simulation:2201.0:-:*:*:*:*:*:* Versions 2201.0 Vulnerable ·Siemens

Remediation

  • Fix · CNA Tecnomatix Plant Simulation V2302 (Siemens) Fixed in V2302.0007

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens Tecnomatix Plant Simulation V2302 V2302.0007

    4 records Highest priority Priority LOW 4 LOW

    Other records, highest priority first

    • TI-2024-15795 NULL pointer dereference in Siemens Tecnomatix Plant Simulation V2201Priority LOW 24
    • TI-2024-15794 NULL pointer dereference in Siemens Tecnomatix Plant Simulation V2201Priority LOW 24
    • TI-2024-15793 NULL pointer dereference in Siemens Tecnomatix Plant Simulation V2201Priority LOW 24

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-23803
  2. 2026-10-03 Alias added: GHSA-2569-97m4-w479

References

  • TI-2023-12136 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2021-08891 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2021-08890 Memory corruption in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2021-08889 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation CVSS 3.1HIGH 7.8
  • TI-2024-15792 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
  • TI-2024-15791 Stack-based buffer overflow in Siemens Tecnomatix Plant Simulation V2201 CVSS 3.1HIGH 7.8
See all 85 →

Sources