Read the docs
TI-2024-24878 Aliases CVE-2024-37368GHSA-9m53-r2vf-94rw

Rockwell Automation FactoryTalk® View SE v11 Information Leakage Vulnerability via Authentication Restriction

Priority MEDIUM 42CWE-287Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
Present
Impact type
Security bypass
Confidentiality · integrity · availability
High · None · None
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-287.

Summary

A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this action is allowed without proper authentication verification.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00498 42nd percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
RockwellFactoryTalk® View SEv11.0—No fix listedCNA
  • FactoryTalk® View SE VendorRockwell Affected v11.0 Fixed in — No fix listed CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*11.0 to before 14.0VulnerableRockwell
  • cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:* Versions 11.0 to before 14.0 Vulnerable ·Rockwell

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-37368
  2. 2026-10-03 Alias added: GHSA-9m53-r2vf-94rw

References

  • TI-2020-09688 Improper input validation in Rockwell FactoryTalk View SE CVSS 3.1CRITICAL 9.0
  • TI-2020-09687 Access control flaw in Rockwell FactoryTalk View SE CVSS 3.1HIGH 8.1
  • TI-2023-01947 FactoryTalk View Machine Edition Vulnerable to Remote Code Execution CVSS 3.1CRITICAL 9.8
  • TI-2020-09686 Information disclosure in Rockwell FactoryTalk View SE CVSS 3.1MEDIUM 4.3
  • TI-2024-04291 Rockwell Automation Datalog Function within in FactoryTalk® View SE contains SQL Injection Vulnerability CVSS 4.0HIGH 8.8
  • TI-2024-30786 FactoryTalk® View Site Edition Remote Code Execution Vulnerability via Lack of Input Validation CVSS 4.0CRITICAL 9.2
See all 17 →

Sources