Command injection in Siemens SINEMA Remote Connect Client
Key facts
- Attack vector
- Local
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.
Summary
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | SINEMA Remote Connect Client | before V3.2 HF1 | V3.2 HF1 | Patch available | CNA |
- SINEMA Remote Connect Client VendorSiemens Affected before V3.2 HF1 Fixed in V3.2 HF1 Patch available CNA
Remediation
- Fix · CNA SINEMA Remote Connect Client (Siemens) Fixed in V3.2 HF1
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens SINEMA Remote Connect Client V3.2 HF1
3 records Highest priority Priority MEDIUM 2 MEDIUM, 1 LOW
Other records, highest priority first
- TI-2024-26501 Command injection in Siemens SINEMA Remote Connect ClientPriority MEDIUM 41
- TI-2024-26502 Command injection in Siemens SINEMA Remote Connect ClientPriority LOW 37
Timeline
- 2026-10-02 Threatist record created from CVE-2024-39567
- 2026-10-03 Alias added: GHSA-qm8q-xxj7-jwh6
References
More Siemens Sinema Remote Connect Client vulnerabilities
- TI-2019-02834 Stack-based buffer overflow in curl CVSS 3.1CRITICAL 9.8
- TI-2024-26501 Command injection in Siemens SINEMA Remote Connect Client CVSS 4.0HIGH 8.5
- TI-2018-12100 Out-of-bounds read in curl CVSS 3.1HIGH 7.5
- TI-2024-26502 Command injection in Siemens SINEMA Remote Connect Client CVSS 4.0HIGH 7.5
- TI-2024-14664 A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1… CVSS 3.1HIGH 7.6
- TI-2024-21105 Insufficient session expiration in Siemens SINEMA Remote Connect Client CVSS 4.0MEDIUM 5.3
Sources
- CVE-2024-39567 · CVE Program
- CVE-2024-39567 · NVD
- FIRST EPSS
- GHSA-qm8q-xxj7-jwh6 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences