Read the docs
TI-2024-26501 Aliases CVE-2024-39568GHSA-9ch7-ph54-c5v4

Command injection in Siemens SINEMA Remote Connect Client

Priority MEDIUM 41CWE-77Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.

Summary

A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00902 59th percentileScored 2026-11-07
Fix Fixed SINEMA Remote Connect Client (Siemens): V3.2 HF1

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSINEMA Remote Connect Clientbefore V3.2 HF1V3.2 HF1Patch availableCNA
  • SINEMA Remote Connect Client VendorSiemens Affected before V3.2 HF1 Fixed in V3.2 HF1 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:*before 3.2VulnerableSiemens
cpe:2.3:a:siemens:sinema_remote_connect_client:3.2:-:*:*:*:*:*:*3.2VulnerableSiemens
  • cpe:2.3:a:siemens:sinema_remote_connect_client:*:*:*:*:*:*:*:* Versions before 3.2 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:sinema_remote_connect_client:3.2:-:*:*:*:*:*:* Versions 3.2 Vulnerable ·Siemens

Remediation

  • Fix · CNA SINEMA Remote Connect Client (Siemens) Fixed in V3.2 HF1

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens SINEMA Remote Connect Client V3.2 HF1

    3 records Highest priority Priority MEDIUM 2 MEDIUM, 1 LOW

    Other records, highest priority first

    • TI-2024-26500 Command injection in Siemens SINEMA Remote Connect ClientPriority MEDIUM 41
    • TI-2024-26502 Command injection in Siemens SINEMA Remote Connect ClientPriority LOW 37

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-39568
  2. 2026-10-03 Alias added: GHSA-9ch7-ph54-c5v4

References

  • TI-2019-02834 Stack-based buffer overflow in curl CVSS 3.1CRITICAL 9.8
  • TI-2024-26500 Command injection in Siemens SINEMA Remote Connect Client CVSS 4.0HIGH 8.5
  • TI-2018-12100 Out-of-bounds read in curl CVSS 3.1HIGH 7.5
  • TI-2024-26502 Command injection in Siemens SINEMA Remote Connect Client CVSS 4.0HIGH 7.5
  • TI-2024-14664 A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1… CVSS 3.1HIGH 7.6
  • TI-2024-21105 Insufficient session expiration in Siemens SINEMA Remote Connect Client CVSS 4.0MEDIUM 5.3
See all 7 →