Read the docs
TI-2024-31850 Aliases CVE-2024-47563GHSA-6j87-vf5h-vj72

Path traversal in Siemens SINEC Security Monitor

Priority LOW 37CWE-22Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
None · Low · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate a file path that is supplied to an endpoint intended to create CSR files. This could allow an unauthenticated remote attacker to create files in writable directories outside the intended location and thus compromise integrity of files in those writable directories.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00547 46th percentileScored 2026-11-07
Fix Fixed SINEC Security Monitor (Siemens): V4.9.0

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensSINEC Security Monitorbefore V4.9.0V4.9.0Patch availableCNA
  • SINEC Security Monitor VendorSiemens Affected before V4.9.0 Fixed in V4.9.0 Patch available CNA

CPE configurations NVD · 1

CPEVersionsRoleVendor
cpe:2.3:a:siemens:sinec_security_monitor:*:*:*:*:*:*:*:*before 4.9.0VulnerableSiemens
  • cpe:2.3:a:siemens:sinec_security_monitor:*:*:*:*:*:*:*:* Versions before 4.9.0 Vulnerable ·Siemens

Remediation

  • Fix · CNA SINEC Security Monitor (Siemens) Fixed in V4.9.0

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens SINEC Security Monitor V4.9.0

    4 records Highest priority Priority MEDIUM 2 MEDIUM, 2 LOW

    Other records, highest priority first

    • TI-2024-31840 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0).Priority MEDIUM 44
    • TI-2024-31849 Command injection in Siemens SINEC Security MonitorPriority MEDIUM 42
    • TI-2024-31851 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0).Priority LOW 24

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-47563
  2. 2026-10-03 Alias added: GHSA-6j87-vf5h-vj72

References

  • TI-2024-31840 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). CVSS 4.0CRITICAL 9.4
  • TI-2024-31849 Command injection in Siemens SINEC Security Monitor CVSS 4.0CRITICAL 9.3
  • TI-2025-27268 Improper authorization in Siemens SINEC Security Monitor CVSS 4.0HIGH 8.4
  • TI-2025-27269 Improper input validation in Siemens SINEC Security Monitor CVSS 4.0HIGH 7.1
  • TI-2026-22042 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). CVSS 4.0MEDIUM 5.3
  • TI-2024-31851 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). CVSS 4.0MEDIUM 5.3

Sources