A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0).
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- None · Low · None
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate that user input complies with a list of allowed values. This could allow an authenticated remote attacker to compromise the integrity of the configuration of the affected application.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
- Fix · CNA SINEC Security Monitor (Siemens) Fixed in V4.9.0
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens SINEC Security Monitor V4.9.0
4 records Highest priority Priority MEDIUM 2 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2024-31840 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0).Priority MEDIUM 44
- TI-2024-31849 Command injection in Siemens SINEC Security MonitorPriority MEDIUM 42
- TI-2024-31850 Path traversal in Siemens SINEC Security MonitorPriority LOW 37
Timeline
- 2026-10-02 Threatist record created from CVE-2024-47565
- 2026-10-03 Alias added: GHSA-gmhf-r4cx-xf3x
References
More Siemens Sinec Security Monitor vulnerabilities
- TI-2024-31840 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). CVSS 4.0CRITICAL 9.4
- TI-2024-31849 Command injection in Siemens SINEC Security Monitor CVSS 4.0CRITICAL 9.3
- TI-2025-27268 Improper authorization in Siemens SINEC Security Monitor CVSS 4.0HIGH 8.4
- TI-2024-31850 Path traversal in Siemens SINEC Security Monitor CVSS 4.0MEDIUM 6.9
- TI-2025-27269 Improper input validation in Siemens SINEC Security Monitor CVSS 4.0HIGH 7.1
- TI-2026-22042 A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). CVSS 4.0MEDIUM 5.3
Sources
- CVE-2024-47565 · CVE Program
- CVE-2024-47565 · NVD
- FIRST EPSS
- GHSA-gmhf-r4cx-xf3x · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences