XML external entity injection in Siemens Polarion V2310
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Information disclosure
- Confidentiality · integrity · availability
- High · None · None
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-611 and the CVSS impact.
Summary
A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The affected application contains a XML External Entity Injection (XXE) vulnerability in the docx import feature. This could allow an authenticated remote attacker to read arbitrary data from the application server.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Siemens | Polarion V2310 | all versions | — | No fix listed | CNA |
| Siemens | Polarion V2404 | before V2404.4 | V2404.4 | Patch available | CNA |
Remediation
- Fix · CNA Polarion V2404 (Siemens) Fixed in V2404.4
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Siemens Polarion V2404 V2404.4
3 records Highest priority Priority LOW 3 LOW
Other records, highest priority first
- TI-2024-34373 SQL injection in Siemens Polarion V2310Priority LOW 32
- TI-2024-34375 Cross-site scripting in Siemens Polarion V2310Priority LOW 23
Timeline
- 2026-10-02 Threatist record created from CVE-2024-51445
- 2026-10-03 Alias added: GHSA-66q5-cm35-phr2
References
More Siemens Polarion Alm vulnerabilities
- TI-2024-15807 Improper authentication in Siemens Polarion ALM CVSS 3.1CRITICAL 9.8
- TI-2024-34376 A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All… CVSS 4.0MEDIUM 6.9
- TI-2023-27468 Incorrect default permissions in Siemens Polarion ALM CVSS 3.1HIGH 7.8
- TI-2023-13334 XML external entity injection in Siemens Polarion ALM CVSS 3.1HIGH 7.5
- TI-2024-34373 SQL injection in Siemens Polarion V2310 CVSS 4.0HIGH 7.1
- TI-2021-20081 Cross-site scripting in Siemens Polarion ALM CVSS 3.1MEDIUM 6.1
Sources
- CVE-2024-51445 · CVE Program
- CVE-2024-51445 · NVD
- FIRST EPSS
- GHSA-66q5-cm35-phr2 · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences