Read the docs
TI-2024-34375 Aliases CVE-2024-51446GHSA-g96q-8ghc-48j6

Cross-site scripting in Siemens Polarion V2310

Priority LOW 23CWE-79Published · Updated

Key facts

Attack vector
Network
Privileges required
Low
User interaction
Passive
Attack complexity
Low
Attack requirements
None
Impact type
Cross-site scripting
Confidentiality · integrity · availability
None · Low · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-79.

Summary

A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The file upload feature of the affected application improperly sanitizes xml files. This could allow an authenticated remote attacker to conduct a stored cross-site scripting attack by uploading specially crafted xml files that are later downloaded and viewed by other users of the application.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00336 27th percentileScored 2026-11-07
Fix Fixed Polarion V2404 (Siemens): V2404.4

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
SiemensPolarion V2310all versions—No fix listedCNA
SiemensPolarion V2404before V2404.4V2404.4Patch availableCNA
  • Polarion V2310 VendorSiemens Affected all versions Fixed in — No fix listed CNA
  • Polarion V2404 VendorSiemens Affected before V2404.4 Fixed in V2404.4 Patch available CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:a:siemens:polarion_alm:*:*:*:*:*:*:*:*2404.0 to before 2404.4VulnerableSiemens
cpe:2.3:a:siemens:polarion_alm:2310.0:*:*:*:*:*:*:*2310.0VulnerableSiemens
  • cpe:2.3:a:siemens:polarion_alm:*:*:*:*:*:*:*:* Versions 2404.0 to before 2404.4 Vulnerable ·Siemens
  • cpe:2.3:a:siemens:polarion_alm:2310.0:*:*:*:*:*:*:* Versions 2310.0 Vulnerable ·Siemens

Remediation

  • Fix · CNA Polarion V2404 (Siemens) Fixed in V2404.4

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Siemens Polarion V2404 V2404.4

    3 records Highest priority Priority LOW 3 LOW

    Other records, highest priority first

    • TI-2024-34374 XML external entity injection in Siemens Polarion V2310Priority LOW 32
    • TI-2024-34373 SQL injection in Siemens Polarion V2310Priority LOW 32

Timeline

  1. 2026-10-02 Threatist record created from CVE-2024-51446
  2. 2026-10-03 Alias added: GHSA-g96q-8ghc-48j6

References

  • TI-2024-15807 Improper authentication in Siemens Polarion ALM CVSS 3.1CRITICAL 9.8
  • TI-2024-34376 A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All… CVSS 4.0MEDIUM 6.9
  • TI-2023-27468 Incorrect default permissions in Siemens Polarion ALM CVSS 3.1HIGH 7.8
  • TI-2023-13334 XML external entity injection in Siemens Polarion ALM CVSS 3.1HIGH 7.5
  • TI-2024-34374 XML external entity injection in Siemens Polarion V2310 CVSS 4.0HIGH 7.1
  • TI-2024-34373 SQL injection in Siemens Polarion V2310 CVSS 4.0HIGH 7.1
See all 8 →

Sources