Read the docs
TI-2025-00262 Aliases CVE-2025-0327GHSA-4v4v-fcfx-x6mg

Improper privilege management in Schneider Electric EcoStruxure Process Expert

Priority LOW 38CWE-269Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Privilege escalation
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-269.

Summary

CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit trail data and the other acting as server managing client request) that could cause a loss of Confidentiality, Integrity and Availability of engineering workstation when an attacker with standard privilege modifies the executable path of the windows services. To be exploited, services need to be restarted.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00165 5th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure Process ExpertVersions 2020R2; Versions 2021 & 2023 (prior to v4.8.0.5715)—No fix listedCNA
Schneider ElectricEcoStruxure Process Expert for AVEVA System PlatformVersions 2020R2; Versions 2021 & 2023—No fix listedCNA
  • EcoStruxure Process Expert VendorSchneider Electric Affected Versions 2020R2; Versions 2021 & 2023 (prior to v4.8.0.5715) Fixed in — No fix listed CNA
  • EcoStruxure Process Expert for AVEVA System Platform VendorSchneider Electric Affected Versions 2020R2; Versions 2021 & 2023 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-0327
  2. 2026-10-03 Alias added: GHSA-4v4v-fcfx-x6mg

References

  • TI-2018-05679 SQL injection in U.motion Builder software version 1.3.4 KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2022-15561 OS command injection in Schneider Electric SpaceLogic C-Bus Home Controller CVSS 3.1HIGH 8.8
  • TI-2023-04970 Path traversal in Schneider Electric C-Bus Toolkit CVSS 3.1CRITICAL 9.8
  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
See all 888 →

Sources