TI-2025-12880 Aliases CVE-2025-14095GHSA-jvwx-cqx2-8qq4

Privilege boundary violation in Radiometer Products

Priority LOW 29CWE-284Published · Updated

Key facts

Attack vector
Physical
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CNA. Fix status from CNA. Impact type from CWE-284.

Summary

A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.  Other related CVE's are CVE-2025-14096 & CVE-2025-14097. Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required configuration for Exposure: Physical access to the analyzer is needed. Temporary work Around: Only authorized people can physically access the analyzer. Permanent solution: Local Radiometer representatives will contact all affected customers to discuss a permanent solution. Exploit Status: Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication.                                                                                                                                                                                        Note: CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00167 5th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Radiometer Medical ApsABL90 FLEX and ABL90 FLEX PLUS AnalyzersAll application software versions with Windows 7, Windows XP as underlying OS; Application software versions < 3.5MR11 with Windows 10 as underlying OS—No fix listedCNA
Radiometer Medical ApsAQT90 FLEX AnalyzersAll Application software versions <= 8.13 MR2—No fix listedCNA
Radiometer Medical ApsABL800 BASIC and ABL800 FLEX AnalyzersApplication software versions < 6.20 MR2 with Windows 7, Windows XP as underlying OS; Application software versions < 6.20 MR2 with Windows 10 as underlying OS—No fix listedCNA
Radiometer Medical ApsABL9 AnalyzersApplication software versions < 1.5.0—No fix listedCNA
  • ABL90 FLEX and ABL90 FLEX PLUS Analyzers VendorRadiometer Medical Aps Affected All application software versions with Windows 7, Windows XP as underlying OS; Application software versions < 3.5MR11 with Windows 10 as underlying OS Fixed in — No fix listed CNA
  • AQT90 FLEX Analyzers VendorRadiometer Medical Aps Affected All Application software versions <= 8.13 MR2 Fixed in — No fix listed CNA
  • ABL800 BASIC and ABL800 FLEX Analyzers VendorRadiometer Medical Aps Affected Application software versions < 6.20 MR2 with Windows 7, Windows XP as underlying OS; Application software versions < 6.20 MR2 with Windows 10 as underlying OS Fixed in — No fix listed CNA
  • ABL9 Analyzers VendorRadiometer Medical Aps Affected Application software versions < 1.5.0 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.