Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection
Key facts
- Attack vector
- Network
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Code execution
- Confidentiality · integrity · availability
- Low · Low · Low
- Fix status
- No fix listed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-77.
Summary
A vulnerability was identified in Edimax BR-6208AC 1.02/1.03. Affected is the function formStaDrvSetup of the file /goform/formStaDrvSetup of the component Web-based Configuration Interface. The manipulation of the argument rootAPmac leads to command injection. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. Edimax confirms this issue: "The product mentioned, EDIMAX BR-6208AC V2, has reached its End of Life (EOL) status. It is no longer supported or maintained by Edimax, and it is no longer available for purchase in the market. Consequently, there will be no further firmware updates or patches for this device. We recommend users upgrade to newer models for better security." This vulnerability only affects products that are no longer supported by the maintainer.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- Yes
- Technical impact
- Partial
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Edimax | BR-6208AC | 1.02; 1.03 | — | No fix listed | CNA |
- BR-6208AC VendorEdimax Affected 1.02; 1.03 Fixed in — No fix listed CNA
Remediation
No fixed version listed by the sources yet.
Timeline
- 2026-10-02 Threatist record created from CVE-2025-15256
- 2026-10-03 Alias added: GHSA-jc4g-746q-772h
References
Exploit 2
- https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b?source=copy_link
- https://tzh00203.notion.site/EDIMAX-BR-6208AC-V2_1-02-Command-Injection-Vulnerability-in-Web-formStaDrvSetup-handler-2d2b5c52018a803ebd91c200b3e2925b
More Edimax Br-6208ac Firmware vulnerabilities
- TI-2025-43049 EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. CVSS 3.1CRITICAL 9.8
- TI-2026-01629 Edimax BR-6208AC auth_check_userpass2 default credentials CVSS 4.0MEDIUM 6.9
- TI-2025-13599 Edimax BR-6208AC FTP Daemon Service handle_retr path traversal CVSS 4.0MEDIUM 5.3
- TI-2025-13935 Edimax BR-6208AC Web-based Configuration formALGSetup redirect CVSS 4.0MEDIUM 5.1
- TI-2025-13934 Edimax BR-6208AC Web-based Configuration formRoute command injection CVSS 4.0MEDIUM 6.9
Sources
- CVE-2025-15256 · CVE Program
- CVE-2025-15256 · NVD
- FIRST EPSS
- GHSA-jc4g-746q-772h · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences