Read the docs
TI-2025-43049 Aliases CVE-2025-70161GHSA-44vp-c93r-6656

EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection.

Priority HIGH 71CWE-77Published · Updated

Key facts

Attack vector
Network
Privileges required
None
User interaction
None
Attack complexity
Low
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 3.1 · CISA ADP. Fix status from CNA. Impact type from CWE-77.

Summary

EDIMAX BR-6208AC V2_1.02 is vulnerable to Command Injection. This arises because the pppUserName field is directly passed to a shell command via the system() function without proper sanitization. An attacker can exploit this by injecting malicious commands into the pppUserName field, allowing arbitrary code execution.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.27062 98th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by NVD
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
Yes
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
——all versions—No fix listedCNA
  • — Vendor— Affected all versions Fixed in — No fix listed CNA

CPE configurations NVD · 2

CPEVersionsRoleVendor
cpe:2.3:o:edimax:br-6208ac_firmware:1.03:*:*:*:*:*:*:*1.03VulnerableEdimax
cpe:2.3:h:edimax:br-6208ac:2.0:*:*:*:*:*:*:*2.0Running onEdimax
  • cpe:2.3:o:edimax:br-6208ac_firmware:1.03:*:*:*:*:*:*:* Versions 1.03 Vulnerable ·Edimax
  • cpe:2.3:h:edimax:br-6208ac:2.0:*:*:*:*:*:*:* Versions 2.0 Running on ·Edimax

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-70161
  2. 2026-10-03 Alias added: GHSA-44vp-c93r-6656

References

  • TI-2026-01629 Edimax BR-6208AC auth_check_userpass2 default credentials CVSS 4.0MEDIUM 6.9
  • TI-2025-13933 Edimax BR-6208AC Web-based Configuration formStaDrvSetup command injection CVSS 4.0MEDIUM 6.9
  • TI-2025-13599 Edimax BR-6208AC FTP Daemon Service handle_retr path traversal CVSS 4.0MEDIUM 5.3
  • TI-2025-13935 Edimax BR-6208AC Web-based Configuration formALGSetup redirect CVSS 4.0MEDIUM 5.1
  • TI-2025-13934 Edimax BR-6208AC Web-based Configuration formRoute command injection CVSS 4.0MEDIUM 6.9

Sources