TI-2025-21417 Aliases CVE-2025-30056GHSA-jh8x-273m-mx8v

Calling system commands via RunCommand

Priority MEDIUM 42CWE-94Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-94.

Summary

The RunCommand function accepts any parameter, which is then passed for execution in the shell. This allows an attacker to execute arbitrary code on the system.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00233 14th percentileScored 2026-11-07
Fix Fixed CGM CLININET (CGM): 2024.MS4.33

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CGMCGM CLININETbefore 2024.MS4.332024.MS4.33Patch availableCNA
  • CGM CLININET VendorCGM Affected before 2024.MS4.33 Fixed in 2024.MS4.33 Patch available CNA

CPE names Threatist (inferred) · 1

Inferred from how NVD named this product before; not given by a source.

CPEVersionsRoleVendor
cpe:2.3:a:cgm:clininet:*:*:*:*:*:*:*:*——CGM
  • cpe:2.3:a:cgm:clininet:*:*:*:*:*:*:*:* Versions — — ·CGM

Remediation

  • Fix · CNA CGM CLININET (CGM) Fixed in 2024.MS4.33

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-30056
  2. 2026-10-03 Alias added: GHSA-jh8x-273m-mx8v

References

  • TI-2025-43972 Authentication bypass via IP spoofing in CGM CLININET rsyncd CVSS 4.0HIGH 8.8
  • TI-2025-21418 Authenticated RCE with uhcapache privileges in ConvertToPDF CVSS 4.0CRITICAL 9.4
  • TI-2025-43968 Remote code execution via Java deserialization in CGM CLININET CVSS 4.0CRITICAL 9.4
  • TI-2025-21414 RCE on uhcapache user permissions CVSS 4.0CRITICAL 9.4
  • TI-2025-43970 Code injection in CGM CLININET allows remote code execution CVSS 4.0CRITICAL 9.4
  • TI-2025-02033 RCE via Print.pl in uhcPrintServerPrint CVSS 4.0CRITICAL 9.4