Read the docs
TI-2025-24338 Aliases CVE-2025-34189GHSA-6qjx-6pg6-g5q6

Vasion Print (formerly PrinterLogic) Insecure Inter-Process Communication Allows Local Session Hijacking

Priority LOW 30CWE-732Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
Low · High · Low
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-922.

Summary

Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application versions prior to 20.0.1330 (macOS/Linux client deployments) contain a vulnerability in the local inter-process communication (IPC) mechanism. The software stores IPC request and response files inside /opt/PrinterInstallerClient/tmp with world-readable and world-writable permissions. Any local user can craft malicious request files that are processed by privileged daemons, leading to unauthorized actions being executed in other user sessions. This breaks user session isolation, potentially allowing local attackers to hijack sessions, perform unintended actions in the context of other users, and impact system integrity and availability. This vulnerability has been identified by the vendor as: V-2022-004 — Client Inter-process Security.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00253 16th percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix Fixed Print Virtual Appliance Host (Vasion): 1.0.735Print Application (Vasion): 20.0.1330

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
VasionPrint Virtual Appliance Hostbefore 1.0.7351.0.735Patch availableCNA
VasionPrint Applicationbefore 20.0.133020.0.1330Patch availableCNA
  • Print Virtual Appliance Host VendorVasion Affected before 1.0.735 Fixed in 1.0.735 Patch available CNA
  • Print Application VendorVasion Affected before 20.0.1330 Fixed in 20.0.1330 Patch available CNA

CPE configurations NVD · 4

CPEVersionsRoleVendor
cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:*before 20.0.1330VulnerableVasion
cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:*before 1.0.735VulnerableVasion
cpe:2.3:o:apple:macos:-:*:*:*:*:*:*:*not specified by NVDRunning onApple
cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:*not specified by NVDRunning onLinux
  • cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:* Versions before 20.0.1330 Vulnerable ·Vasion
  • cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:* Versions before 1.0.735 Vulnerable ·Vasion
  • cpe:2.3:o:apple:macos:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Apple
  • cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Linux

Remediation

  • Fix · CNA Print Virtual Appliance Host (Vasion) Fixed in 1.0.735
  • Fix · CNA Print Application (Vasion) Fixed in 20.0.1330

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Vasion Print Application, Print Virtual Appliance Host 1.0.735, 20.0.1330

    3 records Highest priority Priority MEDIUM 1 MEDIUM, 2 LOW

    Other records, highest priority first

    • TI-2025-24344 Vasion Print (formerly PrinterLogic) Unquoted Path During Driver Installation Leads to Execution of C:\Program.exePriority MEDIUM 41
    • TI-2025-24337 Vasion Print (formerly PrinterLogic) Local Log Disclosure of Cleartext SessionsPriority LOW 36

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-34189
  2. 2026-10-03 Alias added: GHSA-6qjx-6pg6-g5q6

References

  • TI-2025-24370 Vasion Print (formerly PrinterLogic) Unauthenticated Device Modification CVSS 4.0CRITICAL 10.0
  • TI-2025-24369 Vasion Print (formerly PrinterLogic) Insecure Installation Credentials CVSS 4.0CRITICAL 10.0
  • TI-2025-24368 Vasion Print (formerly PrinterLogic) Unauthenticated Admin APIs Used to Modify SSL Certificates CVSS 4.0CRITICAL 10.0
  • TI-2025-24367 Missing authentication in Vasion Print Virtual Appliance Host CVSS 4.0CRITICAL 10.0
  • TI-2025-24364 Vasion Print (formerly PrinterLogic) Undocumented Hardcoded SSH Key CVSS 4.0CRITICAL 10.0
  • TI-2025-24363 Vasion Print (formerly PrinterLogic) RCE and Password Leaks via API CVSS 4.0CRITICAL 10.0
See all 42 →

Sources