Vasion Print (formerly PrinterLogic) Unquoted Path During Driver Installation Leads to Execution of C:\Program.exe
Key facts
- Attack vector
- Local
- Privileges required
- None
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- Code execution
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-434.
Summary
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints. This vulnerability has been identified by the vendor as: V-2022-006 — Driver Upload Security.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Vasion | Print Virtual Appliance Host | before 1.0.735 | 1.0.735 | Patch available | CNA |
| Vasion | Print Application | before 20.0.1330 | 20.0.1330 | Patch available | CNA |
- Print Virtual Appliance Host VendorVasion Affected before 1.0.735 Fixed in 1.0.735 Patch available CNA
- Print Application VendorVasion Affected before 20.0.1330 Fixed in 20.0.1330 Patch available CNA
CPE configurations NVD · 3
| CPE | Versions | Role | Vendor |
|---|---|---|---|
| cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:* | before 20.0.1330 | Vulnerable | Vasion |
| cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:* | before 1.0.735 | Vulnerable | Vasion |
| cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:* | not specified by NVD | Running on | Microsoft |
- cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:* Versions before 20.0.1330 Vulnerable ·Vasion
- cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:* Versions before 1.0.735 Vulnerable ·Vasion
- cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Microsoft
Remediation
- Fix · CNA Print Virtual Appliance Host (Vasion) Fixed in 1.0.735
- Fix · CNA Print Application (Vasion) Fixed in 20.0.1330
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Vasion Print Application, Print Virtual Appliance Host 1.0.735, 20.0.1330
3 records Highest priority Priority MEDIUM 1 MEDIUM, 2 LOW
Other records, highest priority first
- TI-2025-24337 Vasion Print (formerly PrinterLogic) Local Log Disclosure of Cleartext SessionsPriority LOW 36
- TI-2025-24338 Vasion Print (formerly PrinterLogic) Insecure Inter-Process Communication Allows Local Session HijackingPriority LOW 30
Timeline
- 2026-10-02 Threatist record created from CVE-2025-34195
- 2026-10-03 Alias added: GHSA-5g4v-r3ch-wg6m
References
More Vasion Virtual Appliance Application vulnerabilities
- TI-2025-24370 Vasion Print (formerly PrinterLogic) Unauthenticated Device Modification CVSS 4.0CRITICAL 10.0
- TI-2025-24369 Vasion Print (formerly PrinterLogic) Insecure Installation Credentials CVSS 4.0CRITICAL 10.0
- TI-2025-24368 Vasion Print (formerly PrinterLogic) Unauthenticated Admin APIs Used to Modify SSL Certificates CVSS 4.0CRITICAL 10.0
- TI-2025-24367 Missing authentication in Vasion Print Virtual Appliance Host CVSS 4.0CRITICAL 10.0
- TI-2025-24364 Vasion Print (formerly PrinterLogic) Undocumented Hardcoded SSH Key CVSS 4.0CRITICAL 10.0
- TI-2025-24363 Vasion Print (formerly PrinterLogic) RCE and Password Leaks via API CVSS 4.0CRITICAL 10.0
Sources
- CVE-2025-34195 · CVE Program
- CVE-2025-34195 · NVD
- FIRST EPSS
- GHSA-5g4v-r3ch-wg6m · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences