Read the docs
TI-2025-24344 Aliases CVE-2025-34195GHSA-5g4v-r3ch-wg6m

Vasion Print (formerly PrinterLogic) Unquoted Path During Driver Installation Leads to Execution of C:\Program.exe

Priority MEDIUM 41CWE-434Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Code execution
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-434.

Summary

Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints. This vulnerability has been identified by the vendor as: V-2022-006 — Driver Upload Security.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.0097 62nd percentileScored 2026-11-07
Public exploit Yes 1 exploit referenceTagged by the CNA and NVD
Fix Fixed Print Virtual Appliance Host (Vasion): 1.0.735Print Application (Vasion): 20.0.1330

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
VasionPrint Virtual Appliance Hostbefore 1.0.7351.0.735Patch availableCNA
VasionPrint Applicationbefore 20.0.133020.0.1330Patch availableCNA
  • Print Virtual Appliance Host VendorVasion Affected before 1.0.735 Fixed in 1.0.735 Patch available CNA
  • Print Application VendorVasion Affected before 20.0.1330 Fixed in 20.0.1330 Patch available CNA

CPE configurations NVD · 3

CPEVersionsRoleVendor
cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:*before 20.0.1330VulnerableVasion
cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:*before 1.0.735VulnerableVasion
cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*not specified by NVDRunning onMicrosoft
  • cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:* Versions before 20.0.1330 Vulnerable ·Vasion
  • cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:* Versions before 1.0.735 Vulnerable ·Vasion
  • cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:* Versions not specified by NVD Running on ·Microsoft

Remediation

  • Fix · CNA Print Virtual Appliance Host (Vasion) Fixed in 1.0.735
  • Fix · CNA Print Application (Vasion) Fixed in 20.0.1330

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Vasion Print Application, Print Virtual Appliance Host 1.0.735, 20.0.1330

    3 records Highest priority Priority MEDIUM 1 MEDIUM, 2 LOW

    Other records, highest priority first

    • TI-2025-24337 Vasion Print (formerly PrinterLogic) Local Log Disclosure of Cleartext SessionsPriority LOW 36
    • TI-2025-24338 Vasion Print (formerly PrinterLogic) Insecure Inter-Process Communication Allows Local Session HijackingPriority LOW 30

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-34195
  2. 2026-10-03 Alias added: GHSA-5g4v-r3ch-wg6m

References

  • TI-2025-24370 Vasion Print (formerly PrinterLogic) Unauthenticated Device Modification CVSS 4.0CRITICAL 10.0
  • TI-2025-24369 Vasion Print (formerly PrinterLogic) Insecure Installation Credentials CVSS 4.0CRITICAL 10.0
  • TI-2025-24368 Vasion Print (formerly PrinterLogic) Unauthenticated Admin APIs Used to Modify SSL Certificates CVSS 4.0CRITICAL 10.0
  • TI-2025-24367 Missing authentication in Vasion Print Virtual Appliance Host CVSS 4.0CRITICAL 10.0
  • TI-2025-24364 Vasion Print (formerly PrinterLogic) Undocumented Hardcoded SSH Key CVSS 4.0CRITICAL 10.0
  • TI-2025-24363 Vasion Print (formerly PrinterLogic) RCE and Password Leaks via API CVSS 4.0CRITICAL 10.0
See all 42 →

Sources