Read the docs
TI-2025-34516 Aliases CVE-2025-54754GHSA-x8j7-fjhf-36jc

Cognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded Password

Priority LOW 39CWE-259Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
Passive
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-259.

Summary

An attacker with adjacent access, without authentication, can exploit this vulnerability to retrieve a hard-coded password embedded in publicly available software. This password can then be used to decrypt sensitive network traffic, affecting the Cognex device.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00251 16th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CognexIn-Sight 2000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 7000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 8000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 9000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight Explorer5.x – 6.5.1—No fix listedCNA
  • In-Sight 2000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 7000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 8000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 9000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight Explorer VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-54754
  2. 2026-10-03 Alias added: GHSA-x8j7-fjhf-36jc

References

  • TI-2022-01249 Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
  • TI-2022-01398 Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security CVSS 3.1CRITICAL 9.1
  • TI-2021-12544 Cognex In-Sight OPC Server - Deserialization of Untrusted Data CVSS 3.1CRITICAL 9.8
  • TI-2025-34564 Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay CVSS 4.0HIGH 8.6
  • TI-2025-33825 Cognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side Security CVSS 4.0HIGH 8.6
  • TI-2025-34572 Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information CVSS 4.0HIGH 8.6
See all 12 →

Sources