Read the docs
TI-2025-34564 Aliases CVE-2025-54810GHSA-cr6h-4367-m34r

Cognex In-Sight Explorer and In-Sight Camera Firmware Authentication Bypass by Capture-replay

Priority LOW 39CWE-294Published · Updated

Key facts

Attack vector
Adjacent network
Privileges required
None
User interaction
Passive
Attack complexity
Low
Attack requirements
None
Impact type
Security bypass
Confidentiality · integrity · availability
High · High · High
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-294.

Summary

Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00204 10th percentileScored 2026-11-07
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
CognexIn-Sight 2000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 7000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 8000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight 9000 series5.x – 6.5.1—No fix listedCNA
CognexIn-Sight Explorer5.x – 6.5.1—No fix listedCNA
  • In-Sight 2000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 7000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 8000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight 9000 series VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA
  • In-Sight Explorer VendorCognex Affected 5.x – 6.5.1 Fixed in — No fix listed CNA

Remediation

No fixed version listed by the sources yet.

Timeline

  1. 2026-10-02 Threatist record created from CVE-2025-54810
  2. 2026-10-03 Alias added: GHSA-cr6h-4367-m34r

References

  • TI-2022-01249 Cognex 3D-A1000 Dimensioning System Missing Authentication for Critical Function CVSS 3.1CRITICAL 9.8
  • TI-2022-01398 Cognex 3D-A1000 Dimensioning System Client-Side Enforcement of Server-Side Security CVSS 3.1CRITICAL 9.1
  • TI-2021-12544 Cognex In-Sight OPC Server - Deserialization of Untrusted Data CVSS 3.1CRITICAL 9.8
  • TI-2025-34516 Cognex In-Sight Explorer and In-Sight Camera Firmware Use of Hard-coded Password CVSS 4.0HIGH 8.6
  • TI-2025-33825 Cognex In-Sight Explorer and In-Sight Camera Firmware Client-Side Enforcement of Server-Side Security CVSS 4.0HIGH 8.6
  • TI-2025-34572 Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information CVSS 4.0HIGH 8.6
See all 12 →

Sources