Read the docs
TI-2026-52022 Aliases CVE-2026-74235GHSA-c6qh-q8qg-364c

GFI Exinda AI / ClearView < 7.6.5 Path Traversal via Configuration Download Handler

Priority LOW 32CWE-22Published · Updated

Key facts

Attack vector
Network
Privileges required
High
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
Information disclosure
Confidentiality · integrity · availability
High · None · None
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA. Impact type from CWE-22 and the CVSS impact.

Summary

GFI Exinda AI and ClearView before 7.6.5 contains a path traversal vulnerability in the system maintenance configuration download handler. The wcf_handle_download() function accepts parameters prefixed with v_del_ and appends their values directly to the base configuration directory path without sanitizing for directory traversal sequences. An authenticated attacker with Admin privileges can read arbitrary files from the system in the context of root.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00838 58th percentileScored 2026-11-07
Fix Fixed GFI Exinda AI (GFI Software): 7.6.5GFI ClearView (GFI Software): 7.6.5

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Partial

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
GFI SoftwareGFI Exinda AIbefore 7.6.57.6.5Patch availableCNA
GFI SoftwareGFI ClearViewbefore 7.6.57.6.5Patch availableCNA
  • GFI Exinda AI VendorGFI Software Affected before 7.6.5 Fixed in 7.6.5 Patch available CNA
  • GFI ClearView VendorGFI Software Affected before 7.6.5 Fixed in 7.6.5 Patch available CNA

Remediation

  • Fix · CNA GFI Exinda AI (GFI Software) Fixed in 7.6.5
  • Fix · CNA GFI ClearView (GFI Software) Fixed in 7.6.5

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    GFI ClearView, GFI Exinda AI 7.6.5

    3 records Highest priority Priority LOW 3 LOW

    Other records, highest priority first

    • TI-2026-52023 GFI Exinda AI / ClearView < 7.6.5 Path Traversal via Diagnostic File Deletion HandlerPriority LOW 33
    • TI-2026-52024 GFI Exinda AI / ClearView < 7.6.5 Argument Injection via Tools Iperf ClientPriority LOW 31

Timeline

  1. 2026-10-02 Threatist record created from CVE-2026-74235
  2. 2026-10-03 Alias added: GHSA-c6qh-q8qg-364c

References

  • TI-2025-24238 GFI Kerio Control GFIAgent Missing Authentication on Administrative Interfaces CVSS 4.0CRITICAL 10.0
  • TI-2025-24239 GFI Kerio Control Unsigned System Image Upload Root Code Execution CVSS 4.0CRITICAL 9.4
  • TI-2025-24237 GFI Kerio Control GFIAgent Authentication Bypass via Proxy Forwarding CVSS 4.0CRITICAL 9.5
  • TI-2025-24524 GFI MailEssentials < 21.8 MultiNode Insecure Deserialization CVSS 3.1HIGH 8.8
  • TI-2024-35379 HTTP response splitting in GFI Software Kerio Control CVSS 3.1HIGH 8.8
  • TI-2023-10691 An issue was discovered in GFI Kerio Connect 9.4.1 patch 1 (fixed in 10.0.0). CVSS 3.1HIGH 8.8
See all 63 →

Sources