Beckhoff TcRouter.sys for Windows on x64 and x86 from 1.0.0 before 3.1.0.2365 and TwinCAT.XAR.Base.KM from 1.0.0 before 3.18.1 are affected. Exposed IOCTL function calls (CWE-782) let a local attacker or process with low privileges access I/O ports through the driver. This allows full compromise of the affected devices.
Written with Claude Haiku 5.5 from the sources below · 2026-11-11
Description from the CNA
A local low privileged attacker or process can access I/O ports via TcRouter.sys because of exposed IOCTL function calls resulting in a full compromise of the affected devices.
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- None
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
| Vendor | Product | Affected versions | Fixed in | Status | Source |
|---|---|---|---|---|---|
| Beckhoff Automation | TcRouter.sys for Windows on x64 3.1.0.2364 | 3.1.0.2364 | — | No fix listed | CNA |
| Beckhoff Automation | TcRouter.sys for Windows on x64 <3.1.0.2365 | 1.0.0 to before 3.1.0.2365 | 3.1.0.2365 | Patch available | CNA |
| Beckhoff Automation | TcRouter.sys for Windows on x86 3.1.0.2364 | 3.1.0.2364 | — | No fix listed | CNA |
| Beckhoff Automation | TcRouter.sys for Windows on x86 <3.1.0.2365 | 1.0.0 to before 3.1.0.2365 | 3.1.0.2365 | Patch available | CNA |
| Beckhoff Automation | TwinCAT.XAR.Base.KM 3.16.29 | 3.16.29 | — | No fix listed | CNA |
| Beckhoff Automation | TwinCAT.XAR.Base.KM <3.18.1 | 1.0.0 to before 3.18.1 | 3.18.1 | Patch available | CNA |
- TcRouter.sys for Windows on x64 3.1.0.2364 VendorBeckhoff Automation Affected 3.1.0.2364 Fixed in — No fix listed CNA
- TcRouter.sys for Windows on x64 <3.1.0.2365 VendorBeckhoff Automation Affected 1.0.0 to before 3.1.0.2365 Fixed in 3.1.0.2365 Patch available CNA
- TcRouter.sys for Windows on x86 3.1.0.2364 VendorBeckhoff Automation Affected 3.1.0.2364 Fixed in — No fix listed CNA
- TcRouter.sys for Windows on x86 <3.1.0.2365 VendorBeckhoff Automation Affected 1.0.0 to before 3.1.0.2365 Fixed in 3.1.0.2365 Patch available CNA
- TwinCAT.XAR.Base.KM 3.16.29 VendorBeckhoff Automation Affected 3.16.29 Fixed in — No fix listed CNA
- TwinCAT.XAR.Base.KM <3.18.1 VendorBeckhoff Automation Affected 1.0.0 to before 3.18.1 Fixed in 3.18.1 Patch available CNA
Remediation
Update TcRouter.sys for Windows on x64 and x86 to 3.1.0.2365 and TwinCAT.XAR.Base.KM to 3.18.1. The sources list no fixed version for TcRouter.sys for Windows on x64 3.1.0.2364, TcRouter.sys for Windows on x86 3.1.0.2364, or TwinCAT.XAR.Base.KM 3.16.29.
Written with Claude Haiku 5.5 from the sources below · 2026-11-11
- Fix · CNA TcRouter.sys for Windows on x64 <3.1.0.2365 (Beckhoff Automation) Fixed in 3.1.0.2365
- Fix · CNA TcRouter.sys for Windows on x86 <3.1.0.2365 (Beckhoff Automation) Fixed in 3.1.0.2365
- Fix · CNA TwinCAT.XAR.Base.KM <3.18.1 (Beckhoff Automation) Fixed in 3.18.1
Fixed in the same release
Records fixed by the same vendor advisory or release, as the CNA lists them.
- Release ·
Beckhoff Automation TcRouter.sys for Windows on x64 <3.1.0.2365, TcRouter.sys for Windows on x86 <3.1.0.2365, TwinCAT.XAR.Base.KM <3.18.1 3.1.0.2365, 3.18.1
3 records Highest priority Priority LOW 3 LOW
Other records, highest priority first
- TI-2026-89651 Beckhoff TcRouter.sys IOCTL flaw lets local users move physical memoryPriority LOW 38
- TI-2026-89650 Exposed IOCTL in Beckhoff TcRouter.sys allows physical memory accessPriority LOW 38
Timeline
- 2026-11-11 Threatist record created from CVE-2026-18767
- 2026-11-11 Alias added: GHSA-6c88-88jx-2hcr
- 2026-11-12 Priority changed: MEDIUM → LOW
- 2026-11-12 CISA SSVC decision points changed
References
More Beckhoff Automation vulnerabilities
- TI-2025-27690 Beckhoff: Information leak via Beckhoff Device Manager CVSS 3.1MEDIUM 5.3
- TI-2025-27688 Beckhoff: Arbitrary code execution within privileged processes CVSS 3.1HIGH 8.8
- TI-2026-89651 Beckhoff TcRouter.sys IOCTL flaw lets local users move physical memory CVSS 4.0HIGH 8.5
- TI-2026-89650 Exposed IOCTL in Beckhoff TcRouter.sys allows physical memory access CVSS 4.0HIGH 8.5
- TI-2025-27689 Beckhoff: Performing privileged operations and gaining administrator access CVSS 3.1HIGH 7.8
- TI-2025-27728 Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server CVSS 3.1MEDIUM 5.5
Sources
- CVE-2026-18767 · CVE Program
- CVE-2026-18767 · NVD
- FIRST EPSS
- GHSA-6c88-88jx-2hcr · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences