Read the docs

Beckhoff TcRouter.sys IOCTL flaw lets local users move physical memory

Priority LOW 38CWE-782Published · Updated

Key facts

Attack vector
Local
Privileges required
Low
User interaction
None
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
High · High · High
Fix status
Fixed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Beckhoff TcRouter.sys for Windows on x64 and x86 is affected from 1.0.0 before 3.1.0.2365 and at 3.1.0.2364, and TwinCAT.XAR.Base.KM is affected from 1.0.0 before 3.18.1 and at 3.16.29. Exposed IOCTL function calls lack access control, which lets a local user relocate arbitrary physical memory content (CWE-782). A local attacker with low privileges can exploit this, which the source describes as full compromise of the affected devices.

Written with Claude Haiku 5.5 from the sources below · 2026-11-11

Description from the CNA

A local low privileged attacker can move arbitrary physical memory content via TcRouter.sys because of exposed IOCTL function calls resulting in a full compromise of the affected devices.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00144 3rd percentileScored 2026-11-16
Fix Fixed TcRouter.sys for Windows on x64 <3.1.0.2365 (Beckhoff Automation): 3.1.0.2365TcRouter.sys for Windows on x86 <3.1.0.2365 (Beckhoff Automation): 3.1.0.2365+1 more product

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Beckhoff AutomationTcRouter.sys for Windows on x64 3.1.0.23643.1.0.2364—No fix listedCNA
Beckhoff AutomationTcRouter.sys for Windows on x64 <3.1.0.23651.0.0 to before 3.1.0.23653.1.0.2365Patch availableCNA
Beckhoff AutomationTcRouter.sys for Windows on x86 3.1.0.23643.1.0.2364—No fix listedCNA
Beckhoff AutomationTcRouter.sys for Windows on x86 <3.1.0.23651.0.0 to before 3.1.0.23653.1.0.2365Patch availableCNA
Beckhoff AutomationTwinCAT.XAR.Base.KM 3.16.293.16.29—No fix listedCNA
Beckhoff AutomationTwinCAT.XAR.Base.KM <3.18.11.0.0 to before 3.18.13.18.1Patch availableCNA
  • TcRouter.sys for Windows on x64 3.1.0.2364 VendorBeckhoff Automation Affected 3.1.0.2364 Fixed in — No fix listed CNA
  • TcRouter.sys for Windows on x64 <3.1.0.2365 VendorBeckhoff Automation Affected 1.0.0 to before 3.1.0.2365 Fixed in 3.1.0.2365 Patch available CNA
  • TcRouter.sys for Windows on x86 3.1.0.2364 VendorBeckhoff Automation Affected 3.1.0.2364 Fixed in — No fix listed CNA
  • TcRouter.sys for Windows on x86 <3.1.0.2365 VendorBeckhoff Automation Affected 1.0.0 to before 3.1.0.2365 Fixed in 3.1.0.2365 Patch available CNA
  • TwinCAT.XAR.Base.KM 3.16.29 VendorBeckhoff Automation Affected 3.16.29 Fixed in — No fix listed CNA
  • TwinCAT.XAR.Base.KM <3.18.1 VendorBeckhoff Automation Affected 1.0.0 to before 3.18.1 Fixed in 3.18.1 Patch available CNA

Remediation

Update TcRouter.sys to 3.1.0.2365 for Windows on x64 and x86, and update TwinCAT.XAR.Base.KM to 3.18.1. The sources list no fixed version for TcRouter.sys 3.1.0.2364. The sources list no fixed version for TwinCAT.XAR.Base.KM 3.16.29.

Written with Claude Haiku 5.5 from the sources below · 2026-11-11

  • Fix · CNA TcRouter.sys for Windows on x64 <3.1.0.2365 (Beckhoff Automation) Fixed in 3.1.0.2365
  • Fix · CNA TcRouter.sys for Windows on x86 <3.1.0.2365 (Beckhoff Automation) Fixed in 3.1.0.2365
  • Fix · CNA TwinCAT.XAR.Base.KM <3.18.1 (Beckhoff Automation) Fixed in 3.18.1

Fixed in the same release

Records fixed by the same vendor advisory or release, as the CNA lists them.

  • Release ·

    Beckhoff Automation TcRouter.sys for Windows on x64 <3.1.0.2365, TcRouter.sys for Windows on x86 <3.1.0.2365, TwinCAT.XAR.Base.KM <3.18.1 3.1.0.2365, 3.18.1

    3 records Highest priority Priority LOW 3 LOW

    Other records, highest priority first

    • TI-2026-89650 Exposed IOCTL in Beckhoff TcRouter.sys allows physical memory accessPriority LOW 38
    • TI-2026-89649 Beckhoff TcRouter.sys IOCTL flaw lets local users access I/O portsPriority LOW 38

Timeline

  1. 2026-11-11 Threatist record created from CVE-2026-18769
  2. 2026-11-11 Alias added: GHSA-x59q-qhqr-ghwc
  3. 2026-11-12 Priority changed: MEDIUM → LOW
  4. 2026-11-16 CISA SSVC decision points changed

References

  • TI-2025-27690 Beckhoff: Information leak via Beckhoff Device Manager CVSS 3.1MEDIUM 5.3
  • TI-2025-27688 Beckhoff: Arbitrary code execution within privileged processes CVSS 3.1HIGH 8.8
  • TI-2026-89650 Exposed IOCTL in Beckhoff TcRouter.sys allows physical memory access CVSS 4.0HIGH 8.5
  • TI-2026-89649 Beckhoff TcRouter.sys IOCTL flaw lets local users access I/O ports CVSS 4.0HIGH 8.5
  • TI-2025-27689 Beckhoff: Performing privileged operations and gaining administrator access CVSS 3.1HIGH 7.8
  • TI-2025-27728 Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server CVSS 3.1MEDIUM 5.5