Read the docs

Use after free in Schneider Electric EcoStruxure Power Build Rapsody

Priority LOW 22CWE-416Published · Updated

Key facts

Attack vector
Local
Privileges required
None
User interaction
Active
Attack complexity
Low
Attack requirements
None
Impact type
—
Confidentiality · integrity · availability
Low · Low · Low
Fix status
No fix listed

Attack profile from CVSS 4.0 · CNA. Fix status from CNA.

Summary

Schneider Electric EcoStruxure Power Build Rapsody has affected versions FR-V2.9.1.0 and prior, ESP-V2.8.5.0301 and prior, PT-V2.8.7.0101 and prior, BEL(FR)-V2.8.8.0201 and prior, BEL(EN)-V2.8.3.0201 and prior, INT(EN)-V2.8.4.0401 and prior, INT(FR)-V2.8.6.0000 and prior, and NL-V2.8.2.0000 and prior. A use after free flaw (CWE-416) lets the software use memory after it has been released. A local attacker can trick a user into opening a specially crafted SSD file, which can lead to arbitrary code execution.

Written with Claude Haiku 5.5 from the sources below · 2026-11-11

Description from the CNA

CWE- 416: Use After Free vulnerability exists that could cause arbitrary code execution when a local attacker could trick the end user to open a specially crafted malicious SSD file.

Why it matters now

Exploitation None reported CISA SSVC · not in CISA KEV
EPSS 0.00157 4th percentileScored 2026-11-16
Fix No fix listed No fixed version in the sources yet

SSVC decision points

CISA ADP · SSVC 2.0.3

Exploitation
None
Automatable
No
Technical impact
Total

The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.

Affected products

VendorProductAffected versionsFixed inStatusSource
Schneider ElectricEcoStruxure™ Power Build RapsodyFR-V2.9.1.0 and prior; ESP-V2.8.5.0301 and prior; PT-V2.8.7.0101 and prior; BEL(FR)-V2.8.8.0201 and prior; BEL(EN)-V2.8.3.0201 and prior; INT(EN)-V2.8.4.0401 and prior; INT(FR)-V2.8.6.0000 and prior; NL-V2.8.2.0000 and prior—No fix listedCNA
  • EcoStruxure™ Power Build Rapsody VendorSchneider Electric Affected FR-V2.9.1.0 and prior; ESP-V2.8.5.0301 and prior; PT-V2.8.7.0101 and prior; BEL(FR)-V2.8.8.0201 and prior; BEL(EN)-V2.8.3.0201 and prior; INT(EN)-V2.8.4.0401 and prior; INT(FR)-V2.8.6.0000 and prior; NL-V2.8.2.0000 and prior Fixed in — No fix listed CNA

Remediation

The sources list no fixed version for EcoStruxure™ Power Build Rapsody.

Written with Claude Haiku 5.5 from the sources below · 2026-11-11

Timeline

  1. 2026-11-11 Threatist record created from CVE-2026-119055
  2. 2026-11-11 Alias added: GHSA-j7jm-hcmv-2r6w
  3. 2026-11-16 CISA SSVC decision points changed

References

  • TI-2018-05679 SQL injection in U.motion Builder can cause unwanted code execution KEVCVSS 3.1CRITICAL 9.8
  • TI-2021-05589 Hard-coded credentials in EVlink City , EVlink Parking , and EVlink Smart Wallbox CVSS 3.1CRITICAL 9.8
  • TI-2022-15561 OS command injection in Schneider Electric SpaceLogic C-Bus Home Controller CVSS 3.1HIGH 8.8
  • TI-2023-04970 Path traversal in Schneider Electric C-Bus Toolkit CVSS 3.1CRITICAL 9.8
  • TI-2019-04862 Improper handling of exceptional conditions in Schneider Electric Modicon M580 CVSS 3.1HIGH 7.5
  • TI-2018-05690 Improper handling of exceptional conditions in Modicon M580 Modicon M340 Modicon Quantum… CVSS 3.1HIGH 7.5
See all 889 →