Path traversal in DrayTek Vigor2960 web backup function
Key facts
- Attack vector
- Network
- Privileges required
- Low
- User interaction
- None
- Attack complexity
- Low
- Attack requirements
- None
- Impact type
- —
- Confidentiality · integrity · availability
- High · High · High
- Fix status
- Fixed
Attack profile from CVSS 4.0 · CNA. Fix status from CNA.
Summary
DrayTek Vigor2960 version 1.5.1.6 contains a path traversal flaw (CWE-22) in the function sub_1E084 of /cgi-bin/mainfunction.cgi, reached through the action doWebBackup. Manipulating the option argument lets a remote attacker traverse outside the intended directory. The exploit is public and may be used, according to the source.
Written with Claude Haiku 5.5 from the sources below · 2026-11-16
Description from the CNA
A vulnerability was detected in DrayTek Vigor2960 1.5.1.6. Affected by this issue is the function sub_1E084 of the file /cgi-bin/mainfunction.cgi?action=doWebBackup. The manipulation of the argument option results in path traversal. It is possible to launch the attack remotely. The exploit is now public and may be used. Upgrading to version 1.5.1.7 can resolve this issue. You should upgrade the affected component. The vendor recommends: "1.5.1.6 isn't the latest version of 2960, the latest version fixes many security issues. And we have another one in our release plan which should solve the issues reported."
Why it matters now
SSVC decision points
CISA ADP · SSVC 2.0.3
- Exploitation
- Poc
- Automatable
- No
- Technical impact
- Total
The decision (Track, Attend, Act) also depends on your mission and well-being impact; see CISA's SSVC guide.
Affected products
Remediation
Upgrade DrayTek Vigor2960 to version 1.5.1.7, which fixes this issue. The vendor states that 1.5.1.6 is not the latest version and that the latest version fixes many security issues.
Written with Claude Haiku 5.5 from the sources below · 2026-11-16
- Fix · CNA Vigor2960 (DrayTek) Fixed in 1.5.1.7
Timeline
- 2026-11-15 Threatist record created from CVE-2026-129450
- 2026-11-15 Alias added: GHSA-4279-9fjh-5w5r
- 2026-11-16 CISA SSVC decision points changed
References
More DrayTek vulnerabilities
- TI-2020-12150 Command injection in DrayTek Vigor3900, Vigor2960 and Vigor300B KEVCVSS 3.1CRITICAL 9.8
- TI-2020-06834 Command injection in DrayTek Vigor2960, Vigor3900 and Vigor300B KEVCVSS 3.1CRITICAL 9.8
- TI-2024-12038 OS command injection in DrayTek Vigor2960 and Vigor300B web interface KEVCVSS 4.0MEDIUM 6.9
- TI-2021-03424 Local file inclusion in Draytek VigorConnect lets attackers read files KEVCVSS 3.1HIGH 7.5
- TI-2021-03423 Local file inclusion in Draytek VigorConnect exposes arbitrary files KEVCVSS 3.1HIGH 7.5
- TI-2024-34310 In Draytek Vigor3900 1.5.1.3, attackers can inject malicious commands into… CVSS 3.1CRITICAL 9.8
Sources
- CVE-2026-129450 · CVE Program
- CVE-2026-129450 · NVD
- FIRST EPSS
- GHSA-4279-9fjh-5w5r · GitHub Advisory Database · CC BY 4.0
This product uses the NVD API but is not endorsed or certified by the NVD. Sources and licences