Priority LOW 38
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists on the web server used, that could cause a leak of sensitive data or unauthorized actions on the web server during the time the user is logged in.
CVSS 3.1HIGH 8.8· Network · No auth · User interaction · EPSS 0.00358 · Published 2022-02-04 · No fix listed CWE-352
Priority LOW 35
A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.01169 · Published 2020-12-11 · No fix listed CWE-754
Priority LOW 37
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions) and Modicon M340 controller (all firmware versions), which could ca…
CVSS 3.1HIGH 7.5· Network · No auth · No interaction · EPSS 0.02084 · Published 2019-09-17 · No fix listed CWE-754
Priority MEDIUM 42
CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 prot…
CVSS 3.1HIGH 8.8· Network · Low privileges · No interaction · EPSS 0.01729 · Published 2019-09-17 · No fix listed CWE-284
Priority MEDIUM 40
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause disconnection of active connections when an unus…
CVSS 3.1HIGH 8.6· Network · No auth · No interaction · EPSS 0.01401 · Published 2019-09-17 · No fix listed CWE-754
Priority LOW 25
Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110…
CVSS 3.0MEDIUM 5.4· Network · Low privileges · User interaction · EPSS 0.0056 · Published 2019-03-21 · No fix listed CWE-79
Priority LOW 26
Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302,…
CVSS 3.0MEDIUM 5.4· Network · Low privileges · No interaction · EPSS 0.00871 · Published 2019-03-21 · No fix listed CWE-98
Priority LOW 35
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.01291 · Published 2018-04-18 · No fix listed CWE-119
Priority MEDIUM 46
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.02098 · Published 2018-04-18 · No fix listed CWE-20
Priority MEDIUM 45
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01469 · Published 2018-04-18 · No fix listed CWE-287
Priority LOW 35
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200.
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.01291 · Published 2018-04-18 · No fix listed CWE-119
Priority MEDIUM 46
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.01884 · Published 2018-04-18 · No fix listed CWE-326
Priority MEDIUM 48
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
CVSS 3.0CRITICAL 9.8· Network · No auth · No interaction · EPSS 0.03697 · Published 2018-04-18 · No fix listed CWE-798
Priority MEDIUM 41
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H,…
CVSS 3.0HIGH 7.5· Network · No auth · No interaction · EPSS 0.04807 · Published 2017-06-30 · No fix listed CWE-400