Hirschmann HiOS Switch Platform DoS via Malformed HTTP Request
Hirschmann HiOS Switch Platform devices contain a denial-of-service vulnerability in the integrated web server due to missing validation of HTTP(S) content.
50 records
Hirschmann HiOS Switch Platform devices contain a denial-of-service vulnerability in the integrated web server due to missing validation of HTTP(S) content.
GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access by exploiting a hardcoded string in the authentication mechan…
Hirschmann HiLCOS products OpenBAT, BAT450, WLC, BAT867 contains a firewall filtering vulnerability that fails to correctly filter IPv4 multicast and broadcast traffic when management IP address filtering is disabled, al…
Hirschmann HiOS and HiSecOS products RSP, RSPE, RSPS, RSPL, MSP, EES, EESX, GRS, OS, RED, EAGLE contain an authentication bypass vulnerability in the HTTP(S) management module that allows unauthenticated remote attackers…
Hirschmann HiLCOS OpenBAT and BAT450 products contain a firewall bypass vulnerability in IPv6 IPsec deployments that allows traffic from VPN connections to bypass configured firewall rules.
Hirschmann Industrial HiVision versions 06.0.00 and 07.0.00 prior to 06.0.06 and 07.0.01 contains an improper authorization vulnerability that allows read-only users to gain write access to managed devices by bypassing a…
Hirschmann HiLCOS Classic Platform switches Classic L2E, L2P, L3E, L3P versions prior to 09.0.06 and Classic L2B prior to 05.3.07 contain a credential exposure vulnerability where user passwords are synchronized with SNM…
Hirschmann HiLCOS devices OpenBAT, WLC, BAT300, BAT54 prior to 8.80 and OpenBAT prior to 9.10 are shipped with identical default SSH and SSL keys that cannot be changed, allowing unauthenticated remote attackers to decry…
Hirschmann HiSecOS devices versions prior to 05.3.03 contain a buffer overflow vulnerability in the HTTPS login interface when RADIUS authentication is enabled that allows remote attackers to crash the device or execute…
Hirschmann Industrial HiVision versions prior to 06.0.07 and 07.0.03 contains an authentication bypass vulnerability in the master service that allows unauthenticated remote attackers to execute arbitrary commands with a…
Hirschmann HiOS devices versions prior to 08.1.00 and 07.1.01 contain a denial of service vulnerability in the EtherNet/IP stack where improper handling of packet length fields allows remote attackers to crash or hang th…
Hirschmann Industrial HiVision version 08.1.03 prior to 08.1.04 and 08.2.00 contains a vulnerability in the execution of user-configured external applications that allows a local attacker to execute arbitrary binaries.
Hirschmann EagleSDV version 05.4.01 prior to 05.4.02 contains a denial-of-service vulnerability that causes the device to crash during session establishment when using TLS 1.0 or TLS 1.1.
Hirschmann EagleSDV firmware prior to 05.4.02 contains a denial-of-service vulnerability in TLS session establishment.
HiOS Switch Platform versions 09.1.00 through 09.4.04 and 10.0.00 through 10.3.00 contain a denial-of-service vulnerability in the web interface that allows remote attackers to reboot the affected device by sending a mal…
Hirschmann HiEOS devices versions prior to 01.1.00 contain an authentication bypass vulnerability in the HTTP(S) management module that allows unauthenticated remote attackers to gain administrative access by sending spe…
Hirschmann Industrial HiVision versions 05.0.00 through 08.3.01 prior to 08.3.02 contain an arbitrary code execution vulnerability triggered when an administrator opens a maliciously crafted project file.
HiSecOS web server versions 03.4.00 prior to 04.1.00 contains a privilege escalation vulnerability that allows authenticated users with operator or auditor roles to escalate privileges to the administrator role by sendin…
A stored cross-site scripting (XSS) vulnerability exists in the web management interface of the PPC (Belden) ONT 2K05X router running firmware v1.1.9_206L.
HiSecOS 04.0.01 contains a privilege escalation vulnerability that allows authenticated users to modify their access role through XML-based NETCONF configuration.
The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection.
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an arbitrary firmware image can be loaded because firmware signature verificatio…
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packets can bypass the ModBus enforcer.
On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in…
On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer denial of service.