Priority LOW 24

CGM CLININET is vulnerable to Reflected Cross-Site Scripting (XSS) due to improper neutralization of user-supplied data.

CVSS 4.0MEDIUM 5.1 Network No auth User interaction EPSS 0.005 Published 2026-10-23 No fix listed CWE-79
TI-2025-43974 CVE-2025-30054 · GHSA-xr4f-2f7f-gcx6

Local privilege escalation in CGM CLININET

Priority MEDIUM 41

CGM CLININET is vulnerable to local privilege escalation.

CVSS 4.0CRITICAL 9.3 Local Low privileges No interaction EPSS 0.001 Published 2026-10-23 No fix listed CWE-732
Priority LOW 36

The CGM CLININET application runs the cgm-updater process listening on an open network port without any authentication.

CVSS 4.0MEDIUM 6.9 Network No auth No interaction EPSS 0.00352 Published 2026-10-23 No fix listed CWE-306
Priority LOW 29

The CGM CLININET application stores the production database login and password, as well as RabbitMQ broker credentials, in the SysIO.pl configuration file.

CVSS 4.0MEDIUM 6.8 Local Low privileges No interaction EPSS 0.00098 Published 2026-10-23 Fixed in 2026.MS3 CWE-732
Priority MEDIUM 42

CGM CLININET is vulnerable to Code Injection in the RunCGI.pm component, which dynamically imports the module specified as a query parameter and executes code from untrusted data provided by the user.

CVSS 4.0CRITICAL 9.4 Adjacent network No auth No interaction EPSS 0.00222 Published 2026-10-23 Fixed in 2026.MS3 CWE-94
Priority MEDIUM 40

In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems.

CVSS 4.0CRITICAL 9.0 Adjacent network No auth No interaction EPSS 0.00263 Published 2026-10-23 No fix listed CWE-250
Priority LOW 39

CGM CLININET is vulnerable to Code Injection in the ConvExpr function, which processes Perl expressions into RTF document content.

CVSS 4.0HIGH 8.6 Adjacent network High privileges User interaction EPSS 0.00199 Published 2026-10-23 No fix listed CWE-94
TI-2025-36175 CVE-2025-58406 · GHSA-8r3p-6hh2-9j86

Lack of HTTP Response Headers

Priority LOW 29

The CGM CLININET application respond without essential security HTTP headers, exposing users to client‑side attacks such as clickjacking, MIME sniffing, unsafe caching, weak cross‑origin isolation, and missing transport…

CVSS 4.0MEDIUM 5.3 Network No auth User interaction EPSS 0.00215 Published 2026-03-02 Fixed in 2025.MS3 CWE-693
Priority LOW 29

The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected.

CVSS 4.0MEDIUM 5.3 Network No auth User interaction EPSS 0.002 Published 2026-03-02 Fixed in 2025.MS3 CWE-1021
TI-2025-36173 CVE-2025-58402 · GHSA-29jv-jj9x-v452

Insecure Direct Object Reference Message ID

Priority LOW 31

The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks.

CVSS 4.0HIGH 7.1 Network Low privileges No interaction EPSS 0.00245 Published 2026-03-02 Fixed in 2025.MS4 CWE-639
TI-2025-21423 CVE-2025-30062 · GHSA-442r-f955-7j24

SQL injection in CheckUnitCodeAndKey.pl

Priority LOW 30

In the "CheckUnitCodeAndKey.pl" service, the "validateOrgUnit" function is vulnerable to SQL injection.

CVSS 4.0MEDIUM 6.9 Adjacent network Low privileges No interaction EPSS 0.00205 Published 2026-03-02 Fixed in 2025.MS2 CWE-89
TI-2025-21414 CVE-2025-30044 · GHSA-g323-8g66-2v63

RCE on uhcapache user permissions

Priority MEDIUM 43

In the endpoints "/cgi-bin/CliniNET.prd/utils/usrlogstat_simple.pl", "/cgi-bin/CliniNET.prd/utils/usrlogstat.pl", "/cgi-bin/CliniNET.prd/utils/userlogstat2.pl", and "/cgi-bin/CliniNET.prd/utils/dblogstat.pl", the paramet…

CVSS 4.0CRITICAL 9.4 Adjacent network No auth No interaction EPSS 0.00588 Published 2026-03-02 Fixed in 2025.MS2 CWE-78
Priority MEDIUM 40

The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification.

CVSS 4.0CRITICAL 9.0 Adjacent network No auth No interaction EPSS 0.00099 Published 2026-03-02 Fixed in 2025.MS2 CWE-603
Priority MEDIUM 41

The vulnerability enables an attacker to fully bypass authentication in CGM CLININET and gain access to any active user account by supplying only the username, without requiring a password or any other credentials.

CVSS 4.0CRITICAL 9.0 Adjacent network No auth No interaction EPSS 0.00278 Published 2026-03-02 Fixed in 2025.MS4 CWE-306
TI-2025-09490 CVE-2025-10350 · GHSA-4648-hg34-4w7c

SQL injection in CGM NETRAAD

Priority LOW 39

SQL Injection vulnerability in "imageserver" module when processing C-FIND queries in CGM NETRAAD software allows attacker connected to PACS gaining access to database, including data processed by GCM CLININET software.T…

CVSS 4.0HIGH 8.8 Adjacent network Low privileges No interaction EPSS 0.00201 Published 2026-03-02 Fixed in 7.9.0 CWE-89
Priority LOW 30

In the ReturnUserUnitsXML.pl service, the "getUserInfo" function is vulnerable to SQL injection through the "UserID" parameter.

CVSS 4.0MEDIUM 6.9 Adjacent network Low privileges No interaction EPSS 0.00217 Published 2025-08-27 Fixed in 2024.MS4 CWE-89
Priority LOW 30

In the PrepareCDExportJSON.pl service, the "getPerfServiceIds" function is vulnerable to SQL injection.

CVSS 4.0MEDIUM 6.9 Adjacent network Low privileges No interaction EPSS 0.00217 Published 2025-08-27 Fixed in 2024.MS4 CWE-89
Priority LOW 30

In the PatientService.pl service, the "getPatientIdentifier" function is vulnerable to SQL injection through the "pesel" parameter.

CVSS 4.0MEDIUM 6.9 Adjacent network Low privileges No interaction EPSS 0.00217 Published 2025-08-27 Fixed in 2024.MS4 CWE-89