The product exposes a service that is intended for local only to all network interfaces without any authentication.
The product exposes a service that is intended for local only to all network interfaces without any authentication.
No Hitachi Energy vulnerabilities are listed in CISA KEV.
19 records in Microscada X Sys600 · all components
The product exposes a service that is intended for local only to all network interfaces without any authentication.
The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations.
A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product.
Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC 61850 OPC Server in the Hitachi Energy MicroSCADA X SYS600, M…
Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600.
Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a denial-of-service when ICCP of SYS600 is request to forward any d…
Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any MicroSCADA internal scripts irrespective of the authenticated use…
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600.
A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control ov…
A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system i…
A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product.
An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600.
A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product.
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session.
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product.
A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product.
A vulnerability exists in MicroSCADA X SYS600 product.
A CSV injection vulnerability exists in SYS600.
An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL.